FUNCTION
y These devices are used to maintain the temperature hot and cold, and cannot be used for heating, cooking or refrigeration.
y According to current regulations, food must be at a temperature between 0°C and 3°C for use a cold link or greater than
63°C for use as a hot link.
y Any special use that leaves the scope described hereinabove, as well as any modification to the original conditions will
result in relieving the manufacture from any liability.

TECHNICAL SPECIFICATIONS

Mobile self-service units
y Connection with a spiral cord 2 metres long and equipped with a 16A 2P+T socket.
Reference
Capacity
Overall L x w x H mm
1315 x 840 x 1385
Net weight
Max load
Voltage
Power
Amperage
Cooling capacity
Refrigerating fluid
IP (Protection index)
These units are in compliance with the NF EN 60335-1 and NF EN 60335-2-89 standards.
Reference
Capacity
Overall L x w x H mm
1315 x 840 x 1385
Net weight
Max load
Voltage
Power
Amperage
IP (Protection index)
These units are in compliance with the NF EN 60335-1 and NF EN 60335-2-12 standards.
Reference
Capacity
Overall L x w x H mm
Net weight
Max load
Voltage
Power
Amperage
IP (Protection index)
These units are in compliance with the NF EN 60335-1, NF EN 60335-2-12 (857514) and NF EN 60335-2-50 (857013/857014)
standards.
Server units
y LxWxH: 540x830x900 mm
y For the reference 859525: connection with a spiral cord 2 metres long and equipped with a 16A 2P+T socket. Voltage: 230V
single-phase 50/60 Hz - Power 900W - IP: 21.

ELECTRICAL CONNECTION

y 1 or 2.5 mm² flexible wire –2 phase + earth, PVC insulation in polyurethane sleeve.
y The units must be connected to a single-phase earthed 16 Amp female plug, and will be connected under the control of a
high-sensitivity differential circuit breaker with protection against current overloads.
856013
856014
3 GN 1/1
4 GN 1/1
1640 x 840 x 1385
200 kg
220 kg
100 kg
100 kg
230 V single phase 50 Hz
300 W
1,3 A
272 W
R452a
21
857213
857214
3 GN 1/1
4 GN 1/1
1640 x 840 x 1385
180 kg
200 kg
60 kg
80 kg
230 V single phase 50/60 Hz
1310 W
1750 W
5,7 A
7,6 A
33
857013
3 GN 1/1 H150
1315 x 840 x 1385
140 kg
90 kg
230 V single phase 50/60 Hz
2100 W
9 A
33
ENGLISH
856023
3 GN 1/1
1315 x 885 x 1330
220 kg
100 kg
230 V single phase 50 Hz
300 W
1,3 A
272 W
R452a
21
857223
3 GN 1/1
1315 x 885 x 1330
200 kg
60 kg
230 V single phase 50/60 Hz
1310 W
5,7 A
33
857014
Basin : 2 GN 1/1 H 150
4 GN 1/1 H150
Heated top : 2 GN1/1
1640 x 840 x 1385
1640 x 840 x 1385
160 kg
120 kg
2100 W
9 A
33
856024
4 GN 1/1
1640 x 885 x 1330
240 kg
100 kg
857224
4 GN 1/1
1640 x 885 x 1330
220 kg
80 kg
1750 W
7,6 A
857514
200 kg
100 kg
2180 W
9 A
33
9