6.5.
THE HEART RATE SIGNAL IS INCORRECT
In some case the machine may show "Err" on the heart rate display.
Continued on following page.
Page 6.12
SPIN TRAINER: Service & Maintenance Manual - rev. 2.0
THE HEART RATE
SIGNAL IS
INCORRECT
Is the minimum distance
between machines OK?
YES
Is the receiver positioned
correctly, and are the
connecting cables correctly
routed?
YES
If the TGS is present, is the
TGSRN2ST cable correctly
routed?
YES
1
Are there sources of
electromagnetic noise near
the receiver?
NO
A
NO
Move the machines to
the minimum distance:
see paragraph 5.1.
NO
Position the receiver and
the cable correctly: see
paragraph 11.1
NO
Correctly route the cable:
see paragraph 11.1.
Move the machine away
YES
from the electromagnetic
source or attenuate the
power of the noise: see
paragraph 11.1.