Technogym spin trainer Maintenance Manual page 37

Table of Contents

Advertisement

SPIN TRAINER: Service & Maintenance Manual - rev. 2.0
Connect the tester on the output connector printer cable A441, while the other end is
connected to the machine. Select any training program: as soon as the last input is confirmed
and training starts, the machine will transmit the data through the serial port. The RD LED
should blink red.
(3)
Use a tester to check the continuity of printer cable A441: see paragraph 4.2. "Connecting to
the printer".
(4)
Use a tester to check the continuity of cable SP-8: see paragraph 2.6.2.
RS-232 MINI TESTER
TD
RD
RTS
CTS
DSR
DTR
CD
"Wiring
Page 6.17