Important:
Incorrectly wired connections will produce a short
circuit later on in the product or fuse box. In this case,
you must identify the individual conductors once again
and reconnect them. A mains power switch for turning
the unit ON and OFF may of course be installed in the
mains supply lead.
The light source in this luminaire cannot be replaced.
If the light source needs to be replaced (e.g. at the
end of its service life), the complete luminaire must be
replaced.
Group behaviour
Communication cable (K) permits internal STEINEL
group interconnection of L 665 S and L 666 S.
As many as 10 lights can be interconnected with each
other. Maximum communication cable length is 50 m.
The first light in a group to detect movement switches
the entire group ON. If no further movement is detected
after the time setting selected, the last light in a group
to detect movement switches the entire group OFF.
Note:
– No voltage must be connected to the communica-
tion cable. Do no actuate any external loads.
– Within the interconnected group, all lights operate in
line with their specific control dials.
– The same programme must be selected for all lights.
5. Mounting
• Check all components for damage.
• Do not use the product if it is damaged.
• When installing the sensor-switched light, make sure
the installation site is not exposed to vibration.
• Select an appropriate mounting location, taking the
reach and motion detection into consideration.
Mounting procedure
• Switch OFF power supply (Fig. 
• Unscrew light enclosure from wall mount (Fig. 
• Disconnect terminal (Fig. 
5.3
• Mark drill holes (Fig. 
• Drill holes and insert wall plugs (Fig. 
• Installation with concealed power supply lead
5.5
(Fig. 
)
• Installation with surface-mounted power supply lead
5.6
(Fig. 
)
• Connect conductors (Fig. 
4.1
)
5.1
5.2
)
)
5.4
)
5.7
)
L 665 S
• Adjust house number panel (Fig. 
• Fit house number panel and screw into place
5.8
(Fig. 
)
• Interconnect terminal for house number panel
5.9
(Fig. 
)
• Connect terminal (Fig. 
• Screw light enclosure to wall mount (Fig. 
• Switch ON power supply (Fig. 
• Apply numbers from sheet of self-adhesive house
numbers (Fig. 
Note: refer to sheet of self-adhesive house numbers for
further details on applying them.
L 666 S
• Connect terminal (Fig. 
• Screw light enclosure to wall mount (Fig. 
• Switch ON power supply (Fig. 
• Make settings
6. Function
Factory settings
Programme setting: P 1
Twilight level: 1000 lux
Time setting: 5 seconds
Once installed, the sensor-switched light can be put
into operation. Control dials are provided on the sensor
unit for selecting the time-, twilight- and programme
settings.
• Remove the sensor after pressing the locking tab
with a flat-tip screwdriver (Fig. 
– The sensor-switched light switches to manual
override (permanently ON)
• Make settings with a screwdriver (Fig. 
P1 Standard programme (controller 
– Soft light start / no basic light level
What is soft light start?
The sensor-switched light features a soft light start
function. This means that when turned ON, the light is
not switched directly to maximum output but constant-
ly builds up brightness to 100% within a short period
)
of time. Brightness is also gradually reduced when the
light is switched OFF.
P2 User-friendly programme
– Soft light start + basic light level
– Basic light level ON from twilight setting selected
What is basic light level?
Basic light level provides continuous night-time illumina-
tion at approx. 25% light output. The light only switches
to maximum output (100%) for the time selected in
– 17 –
5.8
)
5.10
)
5.11
)
5.12
)
5.13
)
5.14
5.14
)
"6. Function"
6.1
)
6.2