Figure 6-5 Example Of Optical Transmitting Level Measurement - Hitachi S10mini OD.RING Hardware Manual

Table of Contents

Advertisement

LQE010
OD.RING
MODU.
TX
NO
PR
RX
ERR
CPL
TX
SR
NO
RX
ERR
Disconnect
TX
PR
RX
TX
SR
RX
Short optical fiber
cable
(1 m or less)

Figure 6-5 Example of Optical Transmitting Level Measurement

Take care when handling the optical fiber cable. In particular, do not make
the bend radius smaller than 30 mm, otherwise a wipe breaking may be
caused.
After measurement, clean the optical module and the optical connector.
Since the optical fiber connector of the OD.RING (LQE010) is the FC type
(SMA type for the LQE015), the optical power meter must be applicable to the
FC type (or SMA type). Use the connector adapter (attached to the optical
power meter or separately sold) for the FC type (or the SMA type).
LQE010
OD.RING
MODU.
TX
NO
PR
RX
ERR
CPL
TX
SR
NO
RX
ERR
TX
PR
R X
TX
SR
RX
Connector adapter
(attached to the optical
power meter or separately
sold)
FC type (LQE010)
SMA type (LQE015)
6-17
6 MAINTENANCE
LQE010
TX
PR
RX
ERR
TX
SR
RX
ERR
TX
PR
RX
TX
SR
RX
Optical power meter
Wavelength: 850nm (LQE010)
880nm (LQE015)
OD.RING