4.4.2
DAF Assy / Panel
Figure 4-13 DAF-module.
1. Remove the fixation screw [1] (if the screw is present).
2. Disconnect the cables.
3. Push down the fixation clamp [2], and pull the complete
bracket at the same time backwards. The module is now
unlocked from the LSP bracket and can be removed.
4. To remove the PWB, release the PWB fixation clamps [4],
in order to remove the print from the DAF bracket.
4.4.3
Auto-Scavem Assy / Panel
This panel is mounted in a bracket on the left side of the LSP.
It is not necessary to remove the bracket. This is rather difficult.
1. Release the two PWB fixation clamps at top as well as at
bottom side of the PWB.
2. Remove the cables.
3. Take out the Auto-Scavem PWB.
4.4.4
Small Signal Board (SSB)
1. Unlock the bracket and at the same time pull the bracket
out of the locking holes.
2. Place the SSB bracket on the table.
3. To remove the PWB disconnect the cables, unscrew the
mounting screw and take the PWB out of its bracket.
4.4.5
Large Signal Panel (LSP)
1. Unlock the LSP bracket as described in section "Service
positions".
2. Disconnect the necessary cables.
3. Remove the PWB mounting screws and release the
fixation clamps on the left of the LSP-bracket (the board
hinges at the right side).
4. Remove the board from the bracket.
4.5
Set Reassembly
To reassemble the whole set, do all processes in reverse order.
Be sure that, before the rear cover is mounted:
The mains cord is mounted correctly in its guiding brackets.
All wires/cables are returned in their original positions. This
is very important due to the large "hot" area of the set