Electrical Requirements
Voltage Rating
220 -240AC
Frequency Rating
Power Rating
2.8KW
Your electrical contractor should understand ALL legal
requirements of connection before undertaking any work
or installation.
UNDER NO CIRCUMSTANCES UNDERTAKE
THIS YOURSELF!!!
Note for electrician: This product comes with 13 amp plug
(s) fitted with an RCD unit. We leave it this way for you to
connect it your own way due to continued additions to
current regulations.
1) Connect within current laws and IP directives.
2) (Preferred) Wire into isolated fused feed connecting
directly to the house consumer/service box.
Always use protection against electrical surge. Your shower
should be treated the same as a home computer. A surge
protector should eradicate the possibility of either the
transformer or control panel being burnt out.
Electrical work needs to be signed off by a fully qualified
operative by law. Failure to adhere to this will not only void
your electrical warranty for your shower, but could void
your house insurance too.
Pressure/Water Requirements
We recommend a BAR pressure between 2.5 and 3.4 BAR. If
you have a combi boiler system no problem should be
50HZ
experienced. If you have a gravity feed older type installation
(hot water tank type usually less than 1 BAR) you will almost
certainly need a pump. We cannot advise on which type of
pump is used, location or design because all house plumbing
layouts vary. This is a job for your installer/plumber. The end
delivery however must fall within the scope above.
Important Note Do not exceed 3.4 BAR pressure under any
circumstances. Warranty is void if so as damage will occur. If
you have a combi supply, please use a pressure reducing valve
if required to lower the BAR pressure to the shower.
Please Remember that this product is free standing and is
designed to be pulled away from the wall.
The waste hose must be of a flexible type
The water supply pipes need to be at least 1 metre in length
and must be that of a flexible braided type
DO NOT OVERTIGHTEN THE BRAIDED HOSES AS IT CAN CAUSE
THE CONNECTION TO POP AFTER A FEW WEEKS OF USE.
Always fit easy to get to isolation taps on both hot and cold
water supply (not supplied). Just like a dishwasher or washing
machine, this product MUST be isolated when not in use.
www.insigniarange.com
(1m flexible waste
supplied).
(not supplied).
Last Modified: 07/01/2019
Tools Required
You will require:
Scissors
Knife
Silicone Gun
Spirit Level
Tape Measure
Philips Screwdriver
Electric Drill
Safety Gloves
Safety Glasses
Silicone
Parts Required
RubberGum (supplied)
Plumbers Mait (not supplied)
Hot and cold isolation valves (not supplied)
3 x Braided hoses (not supplied)
05