FIBARO FGFS-101 Operating Manual page 18

Fibaro flood sensor
Hide thumbs Also See for FGFS-101:
Table of Contents

Advertisement

18
i
NOTE
Parameter 75 is ig-
nored when parame-
ter 2 is set to 0.
i
NOTE
In case a time period
set in parameter 76 is
shorter than the one
specified in parameter
75, the device will not
quiet the alarm, it will
remain active.
ADVAnCED PARAMETERS
75. Visual and audible alarms duration
The user can silence the Flood Sensor. Because the Sensor's alarm
may last for a long time, it is possible to turn off visual and audible
alarm signalling to save battery.
The parameter determines time after which alarm will become "quiet"
- still active but the device will go into battery saving mode. Visual or
acoustic alarm will be reactivated after time specified in the parameter
76. When alarm status ceases, alarm will be turned off immediately.
The value of 0 means visual and acoustic alarms are active indefinite-
ly. In battery power mode the Sensor will never go to sleep which
may shorten battery life significantly.
Available settings: 0 - alarms active indefinitely
Default setting:
76. Alarm frame / Basic Set frame retransmission time when re-
taining flood alarm
Parameter determines a time period after which an alarm frame will be
retransmitted. The value of 0 cancels an alarm frame retransmission.
Available settings: 0 - retransmission inactive
Default setting:
77. Flood sensor functionality turned off
Allows for turning of the internal flood sensor. Tamper and built in
temperature sensor will remain active.
Available settings: 0 - Default flood sensor operation (flood detec-
Default setting:
78. Associations in Z-Wave network security mode
This parameter defines how commands are sent in specified associa-
tion groups: as secure or non-secure. Parameter is active only in Z-Wave
network security mode. It does not apply to 1st "Lifeline "group.
Available settings: 0 - none of the groups sent as secure
Default setting:
1-65535 - time in seconds
0
Parameter size:
1-65535 - time in seconds
0
Parameter size:
tion, reactions)
1 - Built-in flood sensor TuRnED OFF (does not
change its state in the main controller, does not
send Alarms and Basic Set frames with flood
state changes. Always visible in the main con-
troller as turned off )
0
Parameter size:
1 - 2nd group "Flood Control" sent as secure
2 - 3rd group "Flood Alarm" sent as secure
4 - 4th group „Tamper" sent as secure
7
Parameter size:
4 [bytes]
4 [bytes]
1 [byte]
1 [byte]