FIBARO FGFS-101 Operating Manual page 17

Fibaro flood sensor
Hide thumbs Also See for FGFS-101:
Table of Contents

Advertisement

Indicated colour = 65536 * RED + 256 * GREEN + BLUE
Colour
Yellow
Turquoise
Orange
Indicator turned off
63. Managing a visual indicator under standard operation
Parameter determines visual indicator's operation. Set to 0 turns the
indicator off, saving a battery life.
Available settings: 0 - visual indicator does not indicate the
Default setting:
73. Temperature measurement compensation
Parameter stores a temperature value to be added to or deducted
from the current temperature measured by internal temperature sen-
sor in order to compensate the difference between air temperature
and temperature at the floor level.
Available settings: -10 000 to +10 000
Default setting:
74. Alarm frame sent to 1st and 4th Association Group activation
(MOVEMEnT_TAMPER / BuTTOn_TAMPER)
The device is able to turn on alarms resulting from sensor's vibrations
(e.g. when the sensor is moved) or the TMP button released.
Available settings: 0 - tamper alarms inactive
Default setting:
Decimal value
Red
Green
Blue
White
temperature
1 - visual indicator indicates the temperature
(blink) every Temperature Measurement Inter-
val (parameter 10, constant current and bat-
tery) or Wake up Interval (battery mode)
2 - visual indicator indicates the temperature
continuously, only in constant power mode
2
Parameter size:
0 (0.00°C)
Parameter size:
1 - button tamper alarm active
2 - movement tamper alarm active
3 - button and movement tampers alarm active
2
Parameter size:
16711680
65280
255
16776960
65535
16750848
16777215
0
1 [byte]
2 [bytes]
1 [byte]
ADVAnCED PARAMETERS
17