16
ADVAnCED PARAMETERS
Available settings: 1-1000 (each 0.01°C)
Default setting:
50. Low temperature alarm threshold
The parameter stores a temperature value, below which visual indi-
cator blinks with a colour determined by a parameter 61 settings. By
default the visual indicator blinks blue.
Available settings: - 10000 to +10000 (each 0.01°C)
Default setting:
51. High temperature alarm threshold
The parameter stores a temperature value, above which visual indica-
tor blinks with a colour determined by the parameter 62 settings. By
default the visual indicator blinks red.
Available settings: - 10000 to +10000 (each 0.01°C)
Default setting:
i
NOTE
The main controller does not interpret negative numbers as decimals.
That's why read value may be different than entered. negative num-
bers are coded in u2 standard.
Decimal
32767
1
0
-1
-10000
-32768
61. Low temperature alarm indicator colour
Parameter stores RGB colour value.
Available settings: 0-16777215
Default setting:
62. High temperature alarm indicator colour
Parameter stores RGB colour value.
Available settings: 0-16777215
Default setting:
i
NOTE
A main controller interprets colours as a sum of it component colours
value. Each colours value is a number from 0 to 255.
50 (0.5°C)
Parameter size:
1500 (15°C) Parameter size:
3500 (35°C) Parameter size:
Hexadecimal (U2)
0x7FFF
0x0001
0x0000
0xFFFF
0xD8F0
0x8000
255
Parameter size:
16711680
Parameter size:
2 [bytes]
2 [bytes]
2 [bytes]
Value in controller
32767
1
0
65535
55536
32768
4 [bytes]
4 [bytes]

Advertisement