5.0 TROUBLESHOOTING

Unit will not operate:
1. Power supply not "ON".
2. Pan not in down position.
3. Defective thermostat or elements.
Pan difficult to tilt:
1. Unit not level.
2. Thrust bearings worn out.
3. Dirt in bearings causing it to bind.
4. Shaft bent.

6.0 PERIODIC MAINTENANCE

1. Grease pivot bearings via lubricating nipple as required. Use Petro-Canada type 0G-
2 or equivalent.
2. Check that screws in element terminals are not loose. Loose connections may
cause arcing and burn off connection causing element failure.