6.
At the end of the 30 minute cook cycle, turn power switch "OFF" and drain the contents of
the cavity.
7.
Thoroughly flush the cavity with clean water and dry with a soft cloth. LEAVE
COMPARTMENT DOOR OPEN WHEN NOT IN USE. The steamer is now ready for use.
Turn off for overnight shutdown.

8.0 TROUBLESHOOTING

GENERAL
PROBLEM
Cooking indicator light
fails to light with
Timer set.
Steam fails to
generate with cooking
indicator light on.
Steams continuously
without the cooking or
ready light on .
Timer dial not turning
Buzzer fails to sound
at end of timer
setting.
PROBABLE CAUSE
a. Main power circuit breaker
tripped.
b. Door interlock switch contacts
not closed.
c. Door interlock switch faulty.
d. Indicator light burned out.
e. Faulty timer contacts.
f. Faulty wiring.
g. Fuse blown.
a. Faulty wiring.
a. Faulty thermostatic switch.
b. Power switch - continuous
steam setting is selected.
a. Faulty timer motor.
b. Faulty wiring.
a. Timer contacts faulty.
b. Buzzer faulty.
c. Faulty wiring.
Locate external circuit breaker for
incoming power and place in ON
position.
Shut cooker door to close switch
contacts. Check alignment of door with
switch.
Replace switch.
Replace light.
Replace timer.
Inspect condition of wire and tightness of
all connections. Correct as needed.
Replace with same rated fuse.
Inspect condition of wire and tightness of
all connections. Correct as needed.
Replace thermostat.
This is normal operation when
"continuous steam" is selected.
Replace timer.
Inspect condition of wire and tightness of
all connections. Correct as needed.
Replace timer.
Replace buzzer.
Inspect condition of wire and tightness of
all connections. Correct as needed.