1. On the idle screen, tap Settings > General > System Settings > Exposure Settings.
2. Select Brightness Priority from the pop-up menu of Exposure mode.
3. Configure and save the following settings:
Parameter
Wide Dynamic
Range
Brightness
Flicker
Description
Configure the value of metering.
Average
Middle Zone
Bottom
Top
Default: Average.
Configure the value of the shutter.
Value: 1/60, 1/90, 1/100, 1/125, 1/180, 1/250, 1/350, 1/500, 1/725,
1/1000, 1/1500, 1/2000, 1/3000, 1/4000, 1/6000, 1/10000
Default: 1/100.
Description
Off or Specify the WDR. The value represents the compression degree of the
dynamic range
Cameras with WDR technology can work perfectly both in the bright and the
dark conditions and present clear images that balances different lighting, so
that you can identify the details.
Off-do not use WDR.
1~5
Default: Off.
Configure the value of brightness.
Note: the valid value is from 0 to 14 and the default value is 6.
Configure the value of camera flicker frequency.
The supported types are as follows:
50 Hz
60 Hz
Off
The indoor lights powered by a 50 Hz or 60 Hz power source may produce
a flicker. You can adjust the camera flicker frequency according to the power
source that the light is powered by.
Default: 50 Hz.