Beeper Indicators; Troubleshooting - Datalogic MAGELLAN 3410VSi Quick Reference Manual

Omni-directional imaging scanner
Hide thumbs Also See for MAGELLAN 3410VSi:
Table of Contents

Advertisement

Beeper Indicators

BEEPER
Power On Beep Single beep
Good Read
Indication
Diagnostics
Programming
Mode
Indications

TROUBLESHOOTING

PROBLEM
Scanner does not power on
No communication with the
host
The scanner will not read
bar codes at all, or reads
poorly
14
MAGELLAN™ 3410VSI
INDICATION
Single beep
Varies (see
"Error
Codes" on page 15
for more
information)
Varies depending
upon the
feature(s) being
configured.
Exchange the power supply with a known good
power supply and retest operation.
Consult your technical support personnel or refer
to your host system manual to verify the proper
interface type, cable and connection port(s) for the
scanner. Verify the interface cable is securely
attached to the host and the scanner.
Make sure the window is clean. Check that the bar
codes are of sufficient quality to be recognized by
the scanner. Wrinkled, smudged, or torn labels
can cause the scanner to not read at all. Scan
known-good labels of an active symbology
check the scanner's read operation.
COMMENT
The Power-On LED indication is a
configurable feature which can be enabled
or disabled. When enabled, this beep
indicates the scanner has finished all its
power-up tests and is now ready for
operation.
The good read beep indication is
configurable. Options include: Enable/
disable, frequency, duration and volume.
See the Product Reference Guide (PRG) for
more information.
The Beeper can provide diagnostic
feedback if the scanner discovers a
problem during SelfTest.
The Beeper will sound as programming
bar code labels are scanned, indicating
progress during scanner configuration.
SOLUTION
a
to

Hide quick links:

Advertisement

Table of Contents
loading