Siemens RDS110.R User Manual page 34

Smart thermostat wireless
Hide thumbs Also See for RDS110.R:
Table of Contents

Advertisement

6
Operating the thermostat on the device
Advanced settings
Other settings
34 | 59
No. Application
Descriptions
settings
35. Off/protection
Configures whether
configuration
the thermostat goes
to the protection
mode or completely
turns off in "OFF"
mode.
36. Heating
Indicates a different
control loop
time for PWM
(Pulse Width
Modulation) pulse
periods. You can
select the default
setting to let the
system configure
the most suitable
heating controller
settings based on
your selected
equipment type.
37. Floor
Floor temperature
temperature
limit for electric floor
limit
heating
38. Optimum start
Pre-heats the room
control
in an optimum way
so that you can get
the scheduled
temperature
setpoint at your
scheduled occupied
time. You can
choose "Warm-up
gradient" to
manually define the
warm-up speed, or
choose "Self-
adaptive" to let the
thermostat learn
and decide the
warm-up speed.
39. Warm-up
The warm-up speed
gradient
that you set to pre-
heat the room.
Factory
Range
settings
Protection Off
Protection
Default
Slow
Medium
Default
Fast
2-position
Self-
adaptive
40 °C
35...60 °C Valid only if
Warm-up
Warm-up
gradient
gradient
Self-
adaptive
30 min/K
0...120 mi
n/K
A6V11562455_en--_b
Dependencies
N/A
N/A
you've
selected the
equipment type
as "Electric
floor heating"
and enabled
the floor
temperature
input in
Changing
system setup
[➙ 35].
Visible only if
you've
activated the
optimum start
control settings
in Changing
system setup
[➙ 35].
Valid only if
you've
activated the
optimum start
control settings
in Changing
system setup