Mounting of adjustable stops
Slide in the adjustable end stops with a nut in the rail of the
cross table.
Set the position of the stops.
Img. 3-12: Adjustable stop
3.7
Mounting the transformer
CAUTION!
The works must only be performed by an electrical specialist or under the control and
supervision of an electrical specialist.
Before starting work on electrical parts or operating agents, the following actions must be taken
in the order given:
disconnect all poles,
secure against restarting,
check that there is no voltage.
Check the cover of the transformer.
Mount the transformer to a stable and dry wall.
Fix the cable in such manner that no danger can arise.
Connect the transformer to the automatic universal table feed.
3.8
Operation universal table feed V250S
ON/ OFF,
switches the universal table feed On or Off.
CIRCUIT-BREAKER,
Safety switch for resetting after an automatic circuit interruption.
RAPID-SWITCH,
activate the rapid feed motor.
Connect the electrical supply cable.
Set the feed speed on speed dial.
Move the direction lever to the direction in which you want the cross table to move.
When the lever is in the central position, the feed motor is halted.
CAUTION!
During its service life, the emergency stop switch is not designed to shut down the table
feed during operation. Use the ON/OFF switch to do this.
INFORMATION
The circuit is automatically disconnected if a current of 4 A circulates through the safety switch
for more than 10 seconds.
Press the CIRCUIT-BREAKER button to start the engine again.