13.3
Description
Gas category 2H (G20)
Diameter of the venturi
restrictor
Nominal Load (gross)
Nominal output
Supply pressure
CO
(full load)
2
O
(full load)
2
Gas consumption
(1)
NO
-emission
x
Mass flow rate flue gases
(minimal load)
Mass flow rate flue gases
(nominal load)
Flue gas temperature
(nominal load)
Gas category 3P (G31)
Diameter of the venturi
restrictor
Nominal Load (gross)
Nominal output
Supply pressure
CO
(full load)
2
O
(full load)
2
Gas consumption
NO
-emission
x
Mass flow rate flue gases
(minimal load)
Mass flow rate flue gases
(nominal load)
Flue gas temperature
(nominal load)
82

Gas details

Unit
mm
3.95
kW
12.1
kW
11.7
11.9
mbar
20.0
vol%
9.3 ± 1.0
vol%
4.3 ± 1.8
1.2
3
m
/h
mg/kWh GCV
22
kg/h
9.1
kg/h
19.0
ºC
42
mm
3.05
kW
11.8
kW
11.4
11.6
mbar
37.0...50.0
vol%
10.0 ± 1.0
vol%
5.7 ± 1.5
kg/h
0.8
mg/kWh GCV
23
kg/h
8.8
kg/h
20.0
ºC
39
1 - Based on 1013.25 mbar and 15°C.
3.95
20.0
19.1
(160-210)
(200-210)
20.0
9.3 ± 1.0
4.3 ± 1.8
1.9
30
9.1
31.4
61
3.05
19.6
18.7
(160-210)
(200-210)
37.0...50.0
10.0 ± 1.0
5.7 ± 1.5
1.4
30
8.8
33.1
56
Installation, Maintenance and Service part
3.95
3.95
24.4
32.2
23.5
30.7
(245-420)
(245-560)
23.8
31.0
(285-420)
(285-560)
31.3
(380-560)
20.0
20.0
9.3 ± 1.0
9.3 ± 1.0
4.3 ± 1.8
4.3 ± 1.8
2.3
3.1
33
37
9.1
9.1
38.4
50.7
57
65
3.05
3.05
23.9
31.5
23.0
30.1
(245-420)
(245-560)
23.3
30.4
(285-420)
(285-560)
30.7
(380-560)
37.0...50.0
37.0...50.0
10.0 ± 1.0
10.0 ± 1.0
5.7 ± 1.5
5.7 ± 1.5
1.7
2.3
33
37
8.8
8.8
40.5
53.3
55
59