Hysteresis - Lochinvar EcoSword LGC 160-210 G P CE Installation, Commissioning, User & Maintenance Instructions

Ecosword gas fired condensing water heater
Table of Contents

Advertisement

Parameter
Description
Last lock-out error
270
Interval between last lock-out
271
and read-out.
Last blocking error
272
Interval between last blocking
273
error and read-out.
Number of flame failures
274
Number of successful ignitions
275
Number of failed ignitions
276
Total of actual days that control
277
is active
Total of actual burning days
278
Selection code
281
n
10.3
0312582_EcoSword_V4.0, 03-05-2021
Unit/Value Adjustable
#
Minutes
Hours
Days
Weeks
#
Minutes
Hours
Days
Weeks
#
×100
#
×10 days
×10 days
#
1 - The maximal setpoint (parameter 207) is factory set at 70. A qualified engineer can modify this
value.
2 - Parameter 005 will only be accessible when parameter 004 is set on ENA.
Note
When parameter 202 is set to Off, the anode warning Ano will not be shown on the
display. Also when there is a problem with the anode protection, this warning will not be
shown. The tank protection cannot be guaranteed. The warranty will be void.

Hysteresis

The water heater does not start immediately when the water temperature is below the
temperature setpoint. To prevent that the water heater switches on and off too often,
there is a margin; the hysteresis.
The standard hysteresis is 10 °C. Thus, the water heater starts to heat up when the water
temperature is 10 °C below the temperature setpoint. Use parameter 003 to change the
hysteresis.
Range
No
C02...S14
--- - no error
No
00n...59n = 0 till 59 minutes
01h...23h = 1 till 23 hours
01d...06d = 1 till 6 days
01...63 = 1 till 63 weeks
No
C02...S14
--- - no error
No
00n...59n = 0 till 59 minutes
01h...23h = 1 till 23 hours
01d...06d = 1 till 6 days
01...63 = 1 till 63 weeks
No
0...990
No
0...990
No
0...990
No
0...990
No
0...990
No
0...990
Default
-
-
-
-
-
-
-
-
-
-
59