EcoSable Gas Fired Condensing Water Heater Installation, Commissioning, User & Maintenance Instructions Models: LGSS 200-600 G P CE and PG P CE LGSS 200-780 G P CE and PG P CE LV 313286 | June 2019...
Page 2
IMPORTANT INFORMATION These instructions must be read and understood before installing, commissioning, operating or maintaining the equipment.
Warranty Refer to the appendix Warranty (see 13.7) for the warranty provisions. Liability User Lochinvar accepts no liability when the water heater is not used correctly and requires the user to: • Read this manual carefully and obey the instructions.
CE-marking and all necessary documentation to obey these regulations. See the compliance section. (on page 4) Lochinvar accepts no liability for claims from third parties when: • The instructions for the correct installation of the water heater are not obeyed.
About this manual Scope This manual gives information about safe and correct use of the water heater and how installation, maintenance and service activities have to be done correctly. You must obey the instructions in this manual. Caution Read this manual carefully before you start the water heater. It can cause personal injury and damage to the water heater when you do not read the manual and/or do not obey the instructions.
Caution Obey the caution instructions to prevent damage of the water heater. Warning Obey the warning instructions to prevent danger of personal injury, and serious damage to the water heater. Document identification Article number Language Version 0313286...
Table of Contents Preface..................3 Copyright................3 Trademarks............... 3 Warranty................3 Liability................3 Compliance............... 4 Regulations............... 4 Contact information............4 About this manual............... 5 Scope................5 Target group..............5 Notation conventions............5 Document identification............6 User part..............11 Introduction................13 Safety..................15 Interface................... 17 Operator interface............17 3.1.1 Control Switch..............17 3.1.2...
Page 8
Turn off the water heater........... 22 4.2.1 Turn off for a short period..........22 4.2.2 Isolate from the mains............22 4.2.3 Turn off for a long period........... 22 Installation, Maintenance and Service part....23 Introduction................25 About the water heater............. 25 Working principle..............25 Safety..................27 Safety instructions............27...
Page 9
8.8.1 Preparation..............45 8.8.2 Mains power..............46 8.8.3 External ON mode switch (optional)........47 8.8.4 Finalization..............47 Commissioning..............47 8.9.1 Filling................47 8.9.2 Air pressure differential............. 47 8.9.3 Gas supply pressure............48 8.9.4 value................49 8.9.5 Turn on the water heater........... 50 8.10 Decommisioning............... 50 8.10.1 Turn off the water heater...........
Page 10
11.3.2 Clean the condensate drain..........64 11.4 Gas-side maintenance............65 11.4.1 Clean the burner.............. 65 11.4.2 Assemble the burner............66 11.4.3 Clean the air inlet filter............66 11.5 Finalization..............67 Troubleshooting................ 69 12.1 Errors and warnings............69 12.1.1 General errors..............69 12.1.2 Displayed errors............... 71 12.1.3 Warnings.................
Introduction The EcoSable water heater stores and heats water for sanitary purposes. Cold water enters the bottom of the tank through the water inlet (1). The heated water leaves the tank at the top through the hot water outlet (2). To operate the water heater, the display (3) and control switch (4) are used.
Safety Lochinvar cannot be held responsible for damages or injuries which can be lead back to: • Failure to follow the instructions provided in this manual. • Carelessness during use or maintenance of the water heater. Every user must study the user part of this manual and must follow the instructions in this part of the manual strictly.
Interface Operator interface The operator interface consists of: • a control switch (see 3.1.1) on the front side of the water heater, between the doors. • a (touchscreen) display (see 3.1.2) to navigate through the menu and on which settings, functions, values and errors can be viewed and entered. The display is completely menu-driven and enables the user to change settings and to verify the status and history of the water heater.
3.1.2.1 Symbols on the display The symbols on the display give visual information about the status of the water heater. Symbol Explanation Water heating is disabled End of water heating (stand-by) Water temperature drops (during water heating and when in stand-by) Water temperature rises (during water heating and when in stand-by) There is a heat demand...
Button Function Scroll up / Raise Scroll down / Lower Status of the water heater During operation, the display shows the status of the water heater. Fig. Display Tank Temperature 60°C Operating Setpoint 60°C Status: Stand-by MENU The following status texts can appear on the display: Status text Explanation Stand-by...
Status text Explanation Heat demand There is a heat demand. External switch The external switch is active. 3.2.1 Operating modes The EcoSable has 3 operating modes: • OFF mode (see 3.2.1.1) • ON mode (see 3.2.1.2) • External ON mode (EXT mode) (see 3.2.1.3) 3.2.1.1 OFF mode In the OFF mode the water heater is de-activated.
Turn on the water heater 4.1.1 Switch to ON mode To start the water heater: Make sure the water heater connects to the mains power supply. Set the control switch on the front of the water heater (see 1) to I. Note It is possible that the water heater starts immediately when you turn on the water heater.
Open the Operating Setpoint control screen. Setpoint 60°C 40°C 85°C ACCEPT BACK Change the water temperature setpoint: Use [+] to increase the setpoint. Use [-] to decrease the setpoint. Press [ACCEPT] to confirm the value or press [BACK] to return to the previous screen.
Introduction About the water heater The EcoSable water heater is intended for heating water for sanitary purposes. The EcoSable is a condensing gas–fired storage water heater with a fan in the air intake. The flue gasses transfer their heat to the water through an efficient heat exchanger. The water heater has a concentric venting connector and can function as an open or as a room-sealed water heater.
Page 26
Fig. EcoSable water heater 1. Water inlet 2. Heat exchanger 3. Water outlet When the temperature is too low, the water heater starts a operating cycle: The controller detects a "heat demand". The fan starts pre-purging. The air proving switch closes when the air pressure differential is sufficient. The spark plug is activated.
Safety Safety instructions For safety instructions on the use of the water heater, refer to Safety (see 2) in the User part of this manual. Warning Installation, maintenance and service must be carried out by a qualified engineer in compliance with the general and local regulations imposed by the gas, water and power supply companies and the fire brigade.
Caution To prevent that you damage the components of the water heater, make sure that it is completely stopped operation before you isolate the water heater from the mains (see 4.2.2). Wait 1 minute after you switch the water heater to OFF mode. Note Any leakage from the tank and/or connections can cause damage to the immediate environment or floors below the level of the boiler room.
Safety devices Fig. Safety devices 1. Temperature sensor 2. Air proving switch 3. Gas control valve 4. Flame probe Safety devices of the water heater: Temperature The water heater controls the water temperature sensor (1) using a temperature sensor: T > 90 ºC (blocking error), max. temperature.
Page 30
Temperature and The T&P valve prevents excessive pressure and pressure relief valve temperature in the tank. (T&P valve) 1- All water heaters have a T&P valve connection. Lochinvar recommends to use a T&P valve. Installation, Maintenance and Service part...
Environmental aspects 6.4.1 Recycling The packaging material is environmentally friendly, recyclable and relatively easy to discard. 6.4.2 Disposal Old end-of-life appliances contain materials that need to be recycled. When you discard devices at the end of their service life, you must obey local legislation related to waste disposal.
Page 32
Installation, Maintenance and Service part...
Water heater Structure of the water heater The water heater has the following main components: Controller (9) The controller monitors and manages all internal processes of the water heater for a safe operation. Display (2) To control the water heater and to verify the status, the touchscreen display has several buttons to operate the water heater.
Page 34
Fig. Components water heater 1. Temperature sensor 9. Controller 2. Display 10. Spark plug 3. Tank 11. Gas control valve 4. Heat exchanger 12. Venturi 5. Combustion chamber 13. Fan 6. Condensate drain 14. Flame probe 7. Drain valve 8. Burner Installation, Maintenance and Service part...
For more safety instructions, refer to Safety instructions (see 6.1). Packaging Lochinvar recommends to unpack the water heater at or near its intended location. Remove the packaging material carefully to prevent damage to the water heater. Conditions The water heater is suitable for room-sealed and for open combustion.
8.2.3 Water composition The water must comply with the regulations for drinking water for human consumption. Water composition Water hardness < 2.05 mmol/l: German hardness < 11.5° dH French hardness < 12.5° fH English hardness < 14.3° e CaCO < 205 ppm Chlorides <...
8.4.2 Hot water connection Note Insulate long hot water pipes to prevent unnecessary energy loss. Install the hot water connection: Install a stop valve (11) in the hot water outlet pipe for service reasons. If applicable, install a temperature gauge (12). Install a T&P valve (3).
This manual does not discus installation type B23. When you need a B23 system, contact Lochinvar for more information. Caution Always make sure that the venting system is mounted into an area suitable for the correct type of installation.
Page 40
Fig. Venting systems IMD-1353 R0 Installation, Maintenance and Service part...
C13/C33 concentric systems Caution The water heater is only CE certified for use with the standard Lochinvar terminal set. The use of a non–standard terminal set can result in incorrect functioning of the water heater. The warranty will be void.
8.7.2 C13/C33 parallel systems Use a standard horizontal or vertical terminal set to install a C13 or a C33 parallel venting system. For additional parts, see the relevant Flue Information Sheet at www.lochinvar.ltd.uk. Description Parallel Venting Venting material PP material Manufacture venting material Muelink &...
Page 43
Diameter flue gas outlet +0,6 -0,6 Diameter air inlet Description parts Lochinvar Part number Wall terminal set ELGPH001 ELGPH002 A wall terminal (1), an adapter, two 1000 mm parallel pipes, two parallel pipes telescopic and a wall plate Wall terminal...
The flue gas terminal must comply to the EN 1856-1 requirements. The maximum allowable recirculation rate is 10% under wind conditions. Contact Lochinvar for more information and/or part numbers of the C43, C53 and C63 venting systems. Installation, Maintenance and Service part...
-0,6 Diameter air inlet Refer to C13/C33 parallel systems (see 8.7.2) for the Lochinvar part numbers. The same parts can be used for the C43, C53 and C63 parallel systems. Use the "adapter box concentric to parallel - water heater side" (part number LV312209) for C63 parallel systems.
Hinge the cover towards the front. Take the cover from the water heater. Fig. Remove the covers The mains power and optional electrical connections have to be connected to the terminal block of the controller, refer to Structure of the water heater (see 7.1). Fig.
8.8.3 External ON mode switch (optional) Install an external ON mode switch: Pull the cables through the grommet. Connect the cables to the two left connections on J17. (see 13.5) Set the appropriate settings in the interface (see 10.5.1). 8.8.4 Finalization When all connections are made, install the cover on the water heater: Place the cover on the water heater.
Disconnect the pressure gauge. Reconnect the hoses of the air proving switch and the gas valve. Fig. Air pressure differential 8.9.3 Gas supply pressure Check the gas supply pressure: Loosen the sealing screw (2) of the test nipple by a few turns. Note Do not completely loosen the sealing screw, it can be difficult to retighten it.
Disconnect the pressure gauge. Tighten the sealing screw in the test nipple. Fig. Gas supply pressure 1. Adjuster screw 2. Sealing screw 3. Gas control valve 4. Gas supply pipe 8.9.4 value Check the CO value: Open the gas supply. Remove the cap (1) from the test nipple (2) of the flue gas outlet pipe.
Set the control switch on the front of the water heater to 0 to turn off the water heater. Remove the measurement probe of the CO meter from the test nipple and place the cap (1) back on the nipple (2). Shut off the gas supply.
Conversion of gas type Caution Conversion of the water heater may only be carried out by a qualified person. Use a special conversion kit to converse the water heater when: • The water heater has to operate on a different family of gases (liquid petroleum gas or natural gas).
Page 52
Installation, Maintenance and Service part...
Settings 10.1 Display The display is completely menu-driven and enables the user to change settings and to verify the status and history of the water heater. For more information about how to use the display, refer to Operator interface (see 3). On the display, press [MENU] to enter the main menu.
10.2.1 Temperatures To change the temperature operating setpoint: From the Temperatures submenu open the Operating Setpoint control screen. Setpoint 60°C 40°C 85°C ACCEPT BACK Change the water temperature setpoint: Use [+] to increase the setpoint. Use [-] to decrease the setpoint. Press [ACCEPT] to confirm the value or press [BACK] to return to the previous screen.
10.3 Appliance Status The Appliance Status submenu shows detailed information on several parts of the appliance. Fig. Appliance status submenu Status: Water Heating Disabled Max Temperature Contact Disabled Air Proving Switch Disabled Igniter on Gas Valve on Flame Detected Target Blower RPM 0rpm Blower RPM 0rpm...
10.4.2 Set the backlight delay To change the backlight delay: From the Display Settings submenu open the Backlight Delay control screen. Backlight Delay 240s (Aan) ACCEPT BACK Change the setting: Use [+] to increase the time that the backlight is on. Use [-] to decrease the time that the backlight is on.
10.5 Appliance information From the main menu, you can open the Appliance Information submenu. The Appliance Information submenu shows information about the operating history of the water heater. Fig. Display - Appliance Information Use the Appliance Information submenu to activate or deactivate the external ON mode switch and to set the ignition attempts.
Change the setting: Use [+] to increase the number of attempts. Use [-] to decrease the number of attempts. Press [ACCEPT] to confirm the value or press [BACK] to return to the previous screen. 10.6 Error history From the main menu, you can open the Error History submenu. The Error History submenu shows the 9 most recent errors of the water heater and the point of time of these errors.
10.7 Error occurrence From the main menu, you can open the Error Occurrence submenu. The Error Occurrence submenu shows the amount of occurred errors of the water heater. Fig. Display - Error Occurrence Ignition Error High-Limit Thermostat Air Proving Switch Flame Detection Error Top Temperature Sensor Bottom Temperature Sensor...
10.9 Service menu The service menu is used to activate the service mode. This service mode can, for example, be used to set the CO2-value at full and at partial load or to check the air pressure differential. Use the "invisible" button on the home screen. Press this button for 10 seconds and the service menu will be visible.
10.9.2 Set the fan speed To change the fan speed: From the Service Menu submenu open the Blower RPM control screen. Blower RPM ACCEPT BACK Use [+] and [-] to change the blower RPM setting. Press [ACCEPT] to confirm the value or press [BACK] to return to the previous screen.
Page 62
Installation, Maintenance and Service part...
(on page 3). If necessary, use a descaling agent to remove the scale and contamination from the tank. Contact Lochinvar for advice on what descaling agent to use. 11.3.2 Clean the condensate drain To clean the condensate drain: Place a tray or towels under the condensate drain to collect water leakage.
11.4 Gas-side maintenance Do gas side maintenance when the water heater does not operate correctly, the air pressure differential is not correct and/or the CO value is not correct. To do gas side maintenance: • Clean the burner (see 11.4.1) •...
Take the fan and burner out of the combustion chamber. Remove the flame rod (12). Do a visual check on the flame rod. Remove the spark plug (13). Do a visual check on the spark plug. Use compressed air to remove all contamination from the outside to the inside of the burner.
Pull the air supply pipe out of the water heater. Remove the filter (4) out of the rubber socket (2). Use a vacuum cleaner to clean the filter. Replace the filter in the rubber socket. Install the air supply pipe back onto the water heater. Place the secure pin.
Page 68
Installation, Maintenance and Service part...
Troubleshooting 12.1 Errors and warnings The water heater can have three different kinds of errors: • General errors (see 12.1.1), which are not displayed • Displayed errors (see 12.1.2), which are divided in two different groups: Lock out errors: when the cause is removed, you can reset the error to resume operation.
Page 70
Indication Cause Measure Water leakage There is a leakage from a threaded Tighten the threaded connection. water connection. There is a condensate leakage Make sure that the condensation water discharge is working properly. If necessary, correct the water discharge. There is a leakage from another nearby Trace the leakage.
Indication Cause Measure value is not correct The unit is not set for the correct gas Make sure that the gas type type corresponds with the information on the rating plate Make sure if the venturi restrictor has the correct diameter, refer to Gas details (see 13.3).
Page 72
Code and description Cause Measure XA5-XXXX The temperature in the tank is above Refer to indication X54-XXXX (see 12.1.3). (lock out error) 95ºC. Make sure that the wiring between Temperature error 1 and 4 of J9 is connected and not High temp limit exceeded damaged.
Page 73
Code and description Cause Measure Not enough pressure differential across Check, after each fix, if the error reappears. the air proving switch, due to: If the error reappears continue in finding the cause. venting system Measure the pressure differential malfunction condensation across the air proving switch, refer to discharge Air pressure differential.
Page 74
Code and description Cause Measure XB2-XXXX No gas Make sure that the main gas supply (lock out error) valve is open. If necessary, open the Ignition error valve. Three unsuccessful Make sure that the manual gas supply ignition attempts. valve, before the gas control valve, is open.
12.1.3 Warnings Note For the coding of the connections, refer to the Electrical wiring diagram (see 13.5). Indication Cause Remark X54-XXXX The temperature in the tank is above Tap off water, so the temperature Temperature warning 90 °C. drops in the water heater. Make sure that there is no scale on the temperature sensor.
Page 76
Installation, Maintenance and Service part...
Appendices 13.1 Technical details Description Unit LGSS 200-600 LGSS 200-780 General Capacity Empty Weight Maximum floor load Maximum operating pressure kPa (bar) 550 (5.5) 550 (5.5) Control thermostat - °C 40 - 85 40 - 85 adjustment range Control thermostat - default °C value Hysteresis upwards -...
Ltd., the enamel-lined steel tank proves to be leaking due to rust or corrosion occurring on the water side, then Lochinvar Ltd. shall offer to replace the defective water heater with an entirely new water heater of equivalent size and quality The warranty period given on the replacement water heater shall be equal to the remaining warranty period of the original water heater that was supplied.
Page 85
Article 5: Scope of the warranty The obligations of Lochinvar Ltd. pursuant to the specified warranty are limited to free delivery from the warehouse of the replacement assemblies, parts or water heater, respectively. Labor, installation and any other costs associated with the replacement will not be accepted by Lochinvar Ltd.
Page 86
Installation, Maintenance and Service part...
Index Electrical wiring diagram...... 82 Switch to ON mode......21 Energy labeling........81 Environmental aspects......31 Error history........58 Error occurrence......... 59 Errors and warnings ......69 About the water heater......25 External ON mode....... 20 About this manual......... 5 External ON mode switch (optional)..47 Air pressure differential .......
Page 88
Turn on the water heater...... 50 Notation conventions ......5 Use........... 21 Use external enable......57 User part..........11 OFF mode.......... 20 ON mode..........20 Operating modes.........20 Operator interface....... 17 Venting system........39 Packaging...........35 Performance check......63 Warnings..........75 Preface..........3 Warranty..........84 Preparation.........64 Water composition.......36 Water connections.......
Page 90
Lochinvar Ltd reserves the right to change 7 Lombard Way, The MXL Centre, Banbury, Oxon, OX16 4TJ specifications without prior notice Tel: +44(0) 1295 269 981, Fax:+44(0) 1295 271 640, Email: info@lochinvar.ltd.uk www.lochinvar.ltd.uk...
Need help?
Do you have a question about the EcoSable LGSS 200-600 G P CE and is the answer not in the manual?
Questions and answers