Electrical Connections; Preparation - Lochinvar EcoSword LGC 160-210 G P CE Installation, Commissioning, User & Maintenance Instructions

Ecosword gas fired condensing water heater
Table of Contents

Advertisement

8.8
w
c
8.8.1
0312582_EcoSword_V4.0, 03-05-2021
Parallel and non-concentric systems
Refer to the table for the correct pipe dimensions of the C43, C53 and C63 parallel
systems.
Description
Manufacture venting material
Construction
Material flue gas outlet
Material air inlet
Diameter flue gas outlet
Diameter air inlet
Refer to C13/C33 parallel systems (see 8.7.2) for the Lochinvar part numbers. The same
parts can be used for the C43, C53 and C63 parallel systems.
Use the "adapter box concentric to parallel - water heater side" (part number LV312209)
for C63 parallel systems.

Electrical connections

Warning
Leave the water heater electrically isolated until you are ready to commission it.
Caution
The water heater is phase-sensitive. It is absolutely essential to connect the mains live
(L) to the live of the water heater and the mains neutral (N) to the neutral of the water
heater. The water heater can handle a potential difference between live (L) and neutral
(N), but the potential difference between live (L) and earth has its restrictions, refer to
displayed errors (see 12.1.2), error F19.

Preparation

Remove the cover of the water heater to make the electrical section and the terminal block
visible:
1.
Use a hex driver to remove the screw (1) at the cover.
2.
Hold the cover at the sides.
3.
Lift the cover and take it from the water heater.
Fig. Remove the cover
Venting material PP
Muelink & Grol
Parallel
PP - Temp. Class T120
+0,6
80
/
mm
-0,6
47