Welbilt FRYMASTER FilterQuick easyTouch Operation Manual page 80

Segmented controller
Hide thumbs Also See for FRYMASTER FilterQuick easyTouch:

Advertisement

Code
E44
RECOVERY FAULT
E45
RECOVERY FAULT – CALL SERVICE
E46
SYSTEM INTERFACE BOARD 1 MISSING - CALL
SERVICE
E51
DUPLICATE BOARD ID - CALL SERVICE
E52
USER INTERFACE CONTROLLER ERROR - CALL
SERVICE
E53
CAN BUS ERROR - CALL SERVICE
E54
USB ERROR
E55
SYSTEM INTERFACE BOARD 2 MISSING - CALL
SERVICE
E61
MISCONFIGURED ENERGY TYPE
E62
VAT NOT HEATING – CHECK ENERGY SOURCE –
XXXF OR XXXC
E63
RATE OF RISE
E64
FILTRATION INTERFACE BOARD FAILURE -
FILTRATION AND TOP OFF DISABLED - CALL
SERVICE
E65
CLEAN OIB SENSOR – XXX F OR XXX C - CALL
SERVICE
E66
DRAIN VALVE OPEN – XXXF OR XXXC
E67
SYSTEM INTERFACE BOARD NOT CONFIGURED
- CALL SERVICE
E68
OIB FUSE TRIPPED – CALL SERVICE
E69
RECIPES NOT AVAILABLE – CALL SERVICE
E70
OQS TEMP HIGH
E71
OQS TEMP LOW
ERROR MESSAGE
Recovery time exceeded maximum time
limit.
Recovery time exceeded maximum time
limit for two or more cycles. Call service.
SIB board 1 connection lost or board
failure. Call service.
Two or more controllers have the same
location ID. Call service.
The controller has an unknown error. Call
service.
Communications are lost between boards.
Call service.
USB connection lost during an update.
SIB board 2 connection lost or board
failure. Call service.
The fryer is configured for the incorrect
energy type. Call service.
The vat is not heating properly.
Rate of rise error occurred during a
recovery test. Ensure the oil level is at the
bottom oil level when cold and at the top
oil level line when at setpoint. On electric
fryers ensure the probe is not touching the
elements.
Filtration Interface Board connections lost
or board failure. Call service.
Gas -The oil is back sensor does not detect
oil. Clean optional oil sensor.
Drain valve is opened during cooking.
Controller is turned on when the SIB board
is not configured. Call service.
The VIB board OIB fuse has tripped and
didn't reset. Call service.
The controller has not been programmed
with product recipes. Replace controller
with factory programmed controller.
Oil temperature is too high for a valid OQS
reading. Filter at a temperature between
300ºF (149ºC) and 375ºF (191ºC).
Oil temperature is too low for a valid OQS
reading. Filter at a temperature between
300ºF (149ºC) and 375ºF (191ºC).
3-6
EXPLANATION

Advertisement

loading