3.2.5 Error Log Codes
See section 1.12.2.1 for instructions to access the Error Log.
Code
E13
TEMPERATURE PROBE FAILURE
E16
HIGH LIMIT 1 EXCEEDED
E17
HIGH LIMIT 2 EXCEEDED
E18
HIGH LIMIT PROBLEM
DISCONNECT POWER
E19
HEATING FAILURE – XXX F or XXX C
E25
HEATING FAILURE - BLOWER
E27
HEATING FAILURE - PRESSURE SWITCH - CALL
SERVICE
E28
HEATING FAILURE – XXX F or XXX C
E29
TOP OFF PROBE FAILURE - CALL SERVICE
E32
DRAIN VALVE NOT OPEN - FILTRATION AND
TOP OFF DISABLED - CALL SERVICE
E33
DRAIN VALVE NOT CLOSED - FILTRATION AND
TOP OFF DISABLED - CALL SERVICE
E34
RETURN VALVE NOT OPEN - FILTRATION AND
TOP OFF DISABLED - CALL SERVICE
E35
RETURN VALVE NOT CLOSED - FILTRATION
AND TOP OFF DISABLED - CALL SERVICE
E36
VALVE INTERFACE BOARD FAILURE -
FILTRATION AND TOP OFF DISABLED - CALL
SERVICE
E37
AUTOMATIC INTERMITTENT FILTRATION
PROBE FAILURE - FILTRATION DISABLED - CALL
SERVICE
E39
CHANGE FILTER PAD
E41
OIL IN PAN ERROR
E42
CLOGGED DRAIN (Gas)
E43
OIL SENSOR FAILURE - CALL SERVICE
ERROR MESSAGE
TEMP Probe reading out of range. Call
service.
High limit temperature is past more than
410°F (210°C), or in CE countries, 395°F
(202°C)
High limit switch has opened.
Vat temperature exceeds 460°F (238°C) and
the high limit has failed to open.
Immediately disconnect power to the fryer
and call service.
Heating Control latch circuit failed.
Heat Contactor failed to latch.
The air pressure switch(s) failed to close.
The air pressure switch has failed closed.
The fryer has failed to ignite and has locked
out the ignition module.
ATO RTD reading out of range. Call service
Drain valve was trying to open and
confirmation is missing
Drain valve was trying to close and
confirmation is missing
Return valve was trying to open and
confirmation is missing
Return valve was trying to close and
confirmation is missing
Valve Interface Board connections lost or
board failure. Call service.
AIF RTD reading out of range. Call service.
25-hour timer has expired, or dirty filter
logic has activated. Change the filter paper
or pad.
The system detects that oil may be present
in the filter pan.
Vat did not empty during filtration. Ensure
the drain is not clogged and follow
prompts.
Oil level sensor may have failed. Call
service.
3-5