2.1.4 OQS (Oil Quality Sensor) Filter
The OQS filter is a function that filters the vat that takes
an oil reading to test the TPM (Total Polar Materials) in
the oil using the built in OQS sensor. This function is
used to determine when the oil has reached the end of
its life and when to dispose. Ensure that the filter pad or
paper is replaced daily to keep the system operating
correctly. For proper operation in high volume or 24-
hour stores, the filter pad or paper must be changed
twice a day.
If CLOSE DISPOSE VALVE is displayed, close the dispose
valve. Press the X (NO) button to exit
DISPLAY
OQS – FILTER NOW?
OIL LEVEL TOO LOW
START FILTRATION
DRAINING
FLUSHING
.
1. The fryer MUST be at setpoint temperature. Press the
filtration menu button or if the TPM button is blinking, press
the TPM button.
2. Select ADVANCED FILTER OPTIONS.
3. Select OQS (Oil Quality Sensor) - FILTER.
4. Press the √ (check - YES) button to start filtration. If the X
(NO) button is selected, filtering is cancelled, and the fryer
resumes normal operation.
5. Displayed if the oil level is too low. Press the √ (check - YES)
button to acknowledge issue and return to idle cook mode.
Check to see if the JIB is low on oil. If JIB is not low and this
continues to occur, contact your FAS.
6. Press the BLUE button to start filtration or the X button to
cancel the filter.
7. No action required as oil drains into filter pan.
8. No action required while the return valve opens, and the vat
is flushed with oil from the filter pan.
2-7
NOTICE
The filter pad or paper must be
.
replaced daily
WARNING
Do not drain more than one frypot at
a time into the built-in filtration unit
to avoid overflow and spillage of hot
oil that may cause severe burns,
slipping and falling.
ACTION