Operation Mode - Bradley Verge Crestt Series Installation And Maintenance Manual

Individual automatic liquid or foam top-fill soap dispenser
Hide thumbs Also See for Verge Crestt Series:
Table of Contents

Advertisement

Verge
Deck-Mounted Soap Dispensers
®

Operation Mode

Operation mode is the normal dispensing mode automatically activated when the soap dispenser is in use. All of the sensors are
active in this mode.
While in operating mode:
• Soap is activated when IR sensor is triggered.
• When the voltage of the battery is lower than 4.6V ±0.2V for 7–10 seconds, the low power LED indicator flashes
green/green and soap dispensing stops.
• When the soap level is below 25% capacity, the low soap LED indicator flashes red.
• When filling the soap fill port with soap, the overfill protection LED indicator becomes steady red and audible indicator
sounds when the tank is at 80% capacity.
• After connecting to power or re-engaging the spout after filling soap tank, keep hand at the sensor to prime the system.
The dispenser will dispense any air from the soap tube, allowing the soap to reach the nozzle. Priming will be complete
within 10 dispenses for first time use. After a soap refill, priming will take fewer than 10 dispenses as soap will already be
present in the soap tube.
LED Indicators
LED flashes green
LED flashes green/green
LED flashes red
LED becomes steady red
with audible indicator
LED flashes green
10
Duration
1 second
ON:
1.2 seconds (green for 0.5 seconds, pause for
0.2 seconds, green for 0.5 seconds)
OFF: 2 seconds
ON:
0.2 seconds
OFF: 2 seconds
Soap dispensing is enabled intermittently
2.5 seconds
0.5 seconds
2/10/2020
Meaning
Dispensing soap
Low power
Low soap
Overfill protection
First time dispensing (priming the system)
Bradley • P20-224 Rev. A: ECO 19-15-015A
Installation

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents