Skoda iV Charger Manual page 38

Hide thumbs Also See for iV Charger:
Table of Contents

Advertisement

Available languages

Available languages

  • ENGLISH, page 1
EN
Ground loss monitor confi guration
DIP-switch 5, in group A confi gures the functionality of the ground loss monitor. By default,
this feature is enabled from the factory.
NOTE: The wallbox will not detect a ground connection if the ground loss monitoring
functionality is disabled.
Ground Loss Monitor Enabled
Ground Loss Monitor Disabled
Group B: Scaling current
NOTE: If the wallbox does not have a CT coil attached (indicated by DIP-switch setting of
group A = 0000x), then the scaling current is the maximum static current of the station.
NOTE: If the wallbox does have a CT coil attached, which is set by DIP-switch group A,
then the scaling current is the maximum facility current per phase.
NOTE: If the static max current is set above the station rating, an error will be shown and
the wallbox will be inoperable.
38
Group A switches
1
2
3
N/A
N/A
N/A
N/A
N/A
N/A
Illustration
4
5
N/A
0
1
2
N/A
1
1
2
3
4
5
3
4
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iv charger connect

Table of Contents