5.4 Assemble wallbox

B
5.4
See the corresponding illustrations in manual B.
1. Install power supply cable.
Caution
Using stranded wires without ferrules may result in improper installation, which can
cause accelerated aging of electric components and/or loss of electric connection.
▶ Use crimped insulated ferrules for 1-phase installation.
▶ Use crimped uninsulated ferrules for 3-phase installation.
a. Strip the outer insulation of the cable to a length of 50 mm, then strip the individual
wires to 12 mm.
b. Route the cables to their connection terminals. Ensure that the bending radius is
within the limits for the cable type.
c. Connect the wires according to the ŠKODA iV Charger model and the color coding
table below.
A. ŠKODA iV Charger Connect+ with kWh meter
a. Connect L1 (as well as L2 and L3 - for 3-phase version) wire(s) of the power supply
cable to L1, L2, L3 terminals of kWh meter.
b. Connect Neutral (N) wire of the power supply cable to the N feed-through terminal,
located next to the kWh meter.
c. Connect PE wire of the power supply cable to the fi rst available slot of the PE feed-
through terminal, located next to the kWh meter.
B. ŠKODA iV Charger and ŠKODA iV Charger Connect without kWh meter:
a. Connect L1 (and L2 and L3 - for 3-phase version) wire(s) of the power supply cable
to L1, L2, L3 slots of the feed-through terminals.
b. Connect Neutral (N) wire of the power supply cable to the N feed-through terminal.
c. Connect PE wire of the power supply cable to the fi rst available slot of the PE feed-
through terminal.
Color coding for power supply cable
Wires
Color
32
L1
L2
Brown
Black
L3
N
Grey
Blue
PE
Green/
Yellow