JLG 800A Service And Maintenance Manual page 52

Table of Contents

Advertisement

ENGINE WILL START AND OPERATE ON GASOLINE AT THIS TEMPERATURE WITH THE RECOMMENDED FLUIDS,
A FULLY CHARGED BATTERY AND THE AID OF A COMPLETE JLG SPECIFIED COLD WEATHER PACKAGE
(IE. ENGINE BLOCK HEATER, BATTERY WARMER AND HYDRAULIC OIL TANK HEATER) .
180° F (82° C)
(HYD. OIL TANK TEMP.)
AMBIENT AIR
TEMPERATURE
120° F (49° C)
110° F (43° C)
100° F (38° C)
90° F (32° C)
80° F (27° C)
70° F (21° C)
60° F (16° C)
50° F (10° C)
40° F (4° C)
30° F (-1° C)
20° F (-7° C)
10° F (-12° C)
0° F (-18° C)
-10° F (-23° C)
-20° F (-29° C)
-30° F (-34° C)
-40° F (-40° C)
Figure 2-2. Engine and Hydraulic Operating Temperature Specifications - GM
3121628
ENGINE WILL START AND OPERATE ON LPG UNAIDED AT THIS TEMPERATURE
WITH THE RECOMMENDED FLUIDS AND A FULLY CHARGED BATTERY.
NOTE: THIS IS THE LOWEST ALLOWABLE OPERATING TEMPERATURE ON LPG.
ENGINE WILL START AND OPERATE ON GASOLINE UNAIDED AT THIS TEMPERATURE
WITH THE RECOMMENDED FLUIDS AND A FULLY CHARGED BATTERY.
NO OPERATION BELOW THIS
AMBIENT TEMPERATURE.
NO OPERATION ABOVE THIS
AMBIENT TEMPERATURE.
ENGINE
SPECIFICATIONS
NO OPERATION BELOW THIS
AMBIENT TEMPERATURE.
EXTENDED DRIVING WITH
HYDRAULIC OIL TANK
TEMPERATURES OF 180° F
(82° C) OR ABOVE.
IF EITHER OR BOTH CONDITIONS
EXIST JLG HIGHLY RECOMMENDS
THE ADDITION OF A HYDRAULIC
OIL COOLER (CONSULT JLG SERVICE).
NO OPERATION ABOVE THIS
PROLONGED OPERATION IN
AMBIENT TEMPERATURE.
AMBIENT AIR TEMPERATURES
OF 100° F (38° C) OR ABOVE.
HYDRAULIC
SPECIFICATIONS
DO NOT START UP HYDRAULIC SYSTEM
WITHOUT HEATING AIDS WITH MOBILE 424
HYDRAULIC OIL BELOW THIS TEMPERATURE.
DO NOT START UP HYDRAULIC SYSTEM
WITHOUT HEATING AIDS AND COLD WEATHER
HYDRAULIC OIL BELOW THIS TEMPERATURE.
NOTE:
1) RECOMMENDATIONS ARE FOR AMBIENT TEMPERATURES
CONSISTENTLY WITHIN SHOWN LIMITS .
2) ALL VALUES ARE ASSUMED TO BE AT SEA LEVEL.
SECTION 2 - GENERAL
AMBIENT AIR
TEMPERATURE
120 F(49 C)
110 F(43 C)
100 F(38 C)
90 F(32 C)
80 F(27 C)
70 F(21 C)
60 F(16 C)
50 F(10 C)
40 F(4 C)
30 F(-1 C)
20 F(-7 C)
10 F(-12 C)
0 F(-18 C)
-10 F(-23 C)
-20 F(-29 C)
-30 F(-34 C)
-40 F(-40 C)
4150548 E
2-11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

800aj

Table of Contents

Save PDF