Download Print this page

HySecurity SWINGSMART-DC Quick Start Steps page 8

Advertisement

t
On P
urn
Emergency Stop
Button (A hole in
the cover provides
accessibility.
C
i
OmPlete the
Refer to the installation manual
to configure User and Installer
Menu options such as gate speed,
IES sensitivity, Close Timer, relay
functionality, etc.
t
g
eSt the
ate
Š Test cycle the gate operator by
pressing the OPEN and CLOSE
buttons. Make sure the gate travels
to full open and close positions.
Š Readjust the limit cams as required.
Š When the gate and operator are
functioning properly, replace the
operator's covers and secure the
latches.
Š Review the Important Safety
Instructions with the end use/
property owner on the proper use
of the gate system.
Page 8
D0324 Rev D
& C
OWer
The USAGE CLASS menu display appears the first time power is
applied. Four sequential displays present information which must be
configured before SwingSmart will function.
the MENU
Turn ON power
Press SELECT.
at the main
Two top
circuit breaker
characters blink.
and toggle
both power
switches ON.
OPEN
PREV
OPEN
PREV
nStall
OPEN
PREV
OPEN
PREV
OPEN
PREV
OmPlete the
To edit
To navigate through
SELECTIONS
Press NEXT.
Continue pressing NEXT
to view all selections.
UC 0
USAGE CLASS
CLOSE
STOP
MENU
RESET
NEXT
SELECT
SH 0
GATE HANDING
CLOSE
MENU
STOP
RESET
NEXT
SELECT
WT 0
GATE WEIGHT (LB)
CLOSE
STOP
MENU
RESET
NEXT
SELECT
LN 0
GATE LENGTH (FT)
CLOSE
STOP
MENU
RESET
NEXT
SELECT
HYSECURITY
GATE CLOSED
CLOSE
STOP
MENU
RESET
NEXT
SELECT
SwingSmart DC Quick Start Steps
S
u
et
P
To choose what is
on the display
between menus
Press SELECT.
Press NEXT or PREV.
Blinking characters
Advance – press NEXT
become static.
Previous – press PREV
SELECTIONS
0 – No Usage Class set.
1 – Single Family residential up to four units.
2 – Multi-family, hotel, etc.
3 – Industrial use, not for general public.
4 – Guarded and monitored facility not for
general public.
SELECTIONS
0 – No handing set. Gate will not move until
handing is set.
Looking at the gate from the secure, operator
side, choose:
R – If the operator is on your right.
L – If the operator is on your left.
SELECTIONS
0 – Not set.
1 – Gate weight: 0 to 300lbs (0 to 136kg)
2 – Gate weight: 301 to 600lbs (136 to 272kg)
3 – Gate weight: 601 to 800lbs (272 to 363kg)
4 – Gate weight: 801 to 1300lbs (363 to 590kg)
SELECTIONS
0 – Not set.
1 – Gate length: 0 to 8ft (0 to 3m)
2 – Gate length: 8 to 12ft (3 to 4m)
3 – Gate length: 12 to 16ft (4 to 5m)
4 – Gate length: 16 to 20ft (5 to 6m)
An audible beep occurs when the initial setup
is complete
Note: One of three gate status displays will
appear depending on the gate's position.
GATE OPEN
GATE CLOSED
GATE STOP
© 2013 www.hysecurity.com
To navigate

Advertisement

loading

This manual is also suitable for:

Swingsmart-dc-20Swingsmart dc