Download Print this page

HySecurity SWINGSMART-DC Quick Start Steps page 4

Advertisement

i
nStall the
The universal elbow on the swing arm lets you easily change the handing from a left-arm configuration
to a right swing arm configuration. The illustration present below show a right hand configuration.
For more detailed steps, refer to the SwingSmart DC Installation and Reference Manual.
a
Warning S
ttaCh
Be sure to place the WARNING
WARNING
signs on the gate. For your
records, take a photograph of the completed
installation site.
Mount bracket approximately 25 inches
(63cm) from base of operator.
The intent of the offset is that, upon gate strike,
the elbow will bend and the taper clamp will slip,
minimizing damage to the gearbox and operator.
a
djuSt the
Š Extend the taper handle and loosen the taper
clamp.
Š Manually swing the gate to full OPEN and
CLOSE positions.
Š Loosen the two Phillips-head screws.
Š Move the limit cams so they trip the
appropriate limit switch at the full OPEN
and CLOSE positions.
Š Retighten the two screws.
Page 4
D0324 Rev D
g
a
ate
ignS
Set screw
(used to prevent locking
of the elbow joint)
Use the supplied set screw to
CAUTION
prevent the arm from locking.
l
S
imit
WitCheS
SwingSmart DC Quick Start Steps
rm
Elbow
joint
Over-
extension stop
Taper clamp
Taper handle
P
OSitiOn the
l
inkage
Use tapped holes and hex
bolts to hold linkage arms
in place (2x) while setting
the limit switches.
Lock nut
NOTE: If the pivot bolt is not vertical,
binding of the arm assembly may occur
during the operation.
Also, the excess on the over-extension stop
must be sawn off to accommodate for the
elbow joint covers.
Limit switches
© 2013 www.hysecurity.com
a
rmS
Limit plate
Limit cam
Phillips-head
screws

Advertisement

loading

This manual is also suitable for:

Swingsmart-dc-20Swingsmart dc