Advertisement

&
Instruction
Manual
Insulation blowing machine
Original Language – English
Intec — 4040 Kodiak Court, Frederick, CO 80504 USA
T: 303-833-6644
Web: www.inteccorp.com
Email: info@inteccorp.com
T: 800-666-1611
Rev Date: 20200303

Advertisement

Table of Contents
loading

Summary of Contents for Intec TURBO FORCE HP2

  • Page 1 & Instruction Manual Insulation blowing machine Original Language – English Intec — 4040 Kodiak Court, Frederick, CO 80504 USA T: 303-833-6644 Web: www.inteccorp.com Email: info@inteccorp.com T: 800-666-1611 Rev Date: 20200303...
  • Page 2 High Productivity and Built-to-Last for High Value Generation. At Intec, we take pride in making your job as easy and profitable as possible. The right system for your needs: Intec strives to provide you with the best combination of portability, functionality, and installation versatility to surpass your desired success.
  • Page 3: Table Of Contents

    System Operation: ..............................6 TROUBLESHOOTING ..................15 SPECIFICATIONS ................... ELECTRICAL DRAWINGS ................... 19 TURBO FORCE HP2 & TURBO FORCE HP MAX -- US ....................19 MAKING A CLAIM FOR DAMAGE OR LOSS ............... 21 WARRANTY ....................22 CERTIFICATIONS ................... 23...
  • Page 4: Symbols

    Instruction Manual Symbols SYMBOL SYMBOL MEANING Indicates an imminently hazardous situation, which, if not avoided, Danger will result in death or serious injury. Indicates a potentially hazardous situation, which, if not avoided, Warning could result in death or serious injury. Indicates a potentially hazardous situation, which, if not avoided, Caution may result in minor or moderate injury.
  • Page 5: How The System Works

    Instruction Manual How the System Works OVERVIEW: Cellulose, Fiberglass, or Stone Wool insulation is loaded into the hopper. The insulation goes thru or under the Breaker Bar. The agitator breaks-up and conditions the insulation for proper density while also sweeping the insulation into the airlock. The airlock transports the insulation into the airstream created by the blower system.
  • Page 6: System Set-Up

    Instruction Manual Set up and Operation System Set-Up: Set system on a dry, level surface. 1. Obtain appropriate protective equipment. 2. Attach hose to machine outlet using a hose clamp. 3. Open slide gate & place pin in desired opening. Note suggested settings are labeled by slide gate.
  • Page 7: System Operation

    Instruction Manual System Operation: 1. Energize System a. Plug in Power Cords. If you do not plan to run Blower #2 you can run system off of 2 power cords. In order to run both Blower(s) all 3 power cords will need to be utilized. b.
  • Page 8 Instruction Manual Variable Speed Button (Green indicating “ON”) Power ON Button; Will not be illuminated prior to being turned on Rotary Control Switch: Must be in “WIRED” position to use a wired remote. Must be in “WIRELESS REMOTE” position to use Wireless remote Variable Speed turned “OFF”...
  • Page 9 Instruction Manual b. It is important to note that Blower #1 must be running for Blower #2 to function. 4. Variable Speed Selection: The Variable Speed Button ring is illuminated green when Variable speed is “ON” illuminated red when Variable speed is “OFF” The Variable Speed can be used to vary the speed of the Primary Blower.
  • Page 10 Instruction Manual Wireless Remote Operations: To utilize the Wireless Remote feature of your system, unplug your wired remote and place the Rotary Control Switch in the “WIRELESS REMOTE” position. “SYNC LED” will only illuminate (green) when re-programming the Wireless Remote to the Wireless Receiver “LEARN BUTTON”...
  • Page 11 Instruction Manual 5. Wait approximately 17 seconds for the Sync LED to stop flashing. Learn Button should return to a steady flashing blue light. 6. Re-Syncing is now complete. Loading Insulation -- Remove packaging and load insulation. Place the Loading Platform in down position by first lifting up, then rotating downwards to rest on top of the system’s handle.
  • Page 12 Instruction Manual B. Fiberglass or Stone Wool: Score bag in ½ bend up to break in ½ Place ½ bag on loading platform with open end facing towards a side & not into the hopper. Slice wrapper in direction shown to allow product to expand into hopper.
  • Page 13 Replace airlock seals if a cut or tear is evident. Airlock seals should be replaced every 300 hours of operation, or once per year. Visit www.inteccorp.com or contact Intec for replacement instructions. Chain Clean and lubricate the chain once per year.
  • Page 14  unexpected repairs are required at times. Making these activities as easy & efficient as possible -- so you can get back up and running in the quickest of manners -- is why Intec Quick-Access was developed. IQ was designed to further your efficiencies by reducing the time it takes to access critical system components.
  • Page 15 Instruction Manual Chains Removing the access panel provides access to the chain driving the two agitators. The airlock chain is accessed thru the revolutionary tilt-back design. Electrical Components Opening the electrical panel provides access to the electronics controlling your TURBO FORCE. Filters Simply slide filter from holder, use compressed air or knock filter on a hard surface to remove contaminants, and replace filter in the...
  • Page 16: Troubleshooting

    Instruction Manual TroubleShooting Problem Likely Cause Remedy Blower #1, Blower #2, Agitator Power cord connection is loose. Ensure appropriate power cord or Airlock LED’s do not light up. connection at machine. Ensure appropriate power cord connection at power source. Power cord not connected at Connect power cord.
  • Page 17 Instruction Manual Problem Likely Cause Remedy Foreign material causing jam in Remove power cords, clear jam, hopper. and restart system. Machine is on, yet no material Slide gate is closed. Open slide gate. comes out of hose. Insulation blockage in hose. Turn system off, remove hose and clear blockage.
  • Page 18 Instruction Manual Problem Likely Cause Remedy Insulation exiting hose is Heavy insulation material. Push slide gate in 1-2 holes. dribbling out. Turn up variable speed on Primary Blower. Turn variable speed selection to ‘off’ to allow for maximum power on Primary Blower. Turn on Auxiliary Blower.
  • Page 19 Antenna –in the down position Extend Antenna straight out from panel. Install the auxiliary antenna provided with your system. Contact Intec for parts. Control Panel needs to be re- Prior to connecting corded Blower and agitator continue to set. remote, all switches must be in run and wired/wireless remotes the “OFF”...
  • Page 20: Specifications

    115 VAC, 13.4 amp, two stage for each blower (115V on line 1; 230V on line 2) 230 VAC, 6.2 amp, two stage for each blower Agitator Motor TURBO FORCE HP2 (NA version) ½ HP, 115VAC, 7.1 amp EU Version 230VAC, 4.5 amp TURBO FORCE HP MAX (NA version) ¾...
  • Page 21: Electrical Drawings

    Instruction Manual Electrical Drawings TURBO FORCE HP2 & TURBO FORCE HP MAX -- US TURBO FORCE HP2 & TURBO FORCE MAX T: 303-833-6644 800-666-1611 www.inteccorp.com Original Language - English...
  • Page 22: Making A Claim For Damage Or Loss

    Instruction Manual Making a Claim for Damage or Loss Your Intec products were carefully packed and thoroughly inspected before leaving our factory. We understand that damage to or defects with your system may unfortunately occur. Please inspect your shipment carefully upon arrival and save the shipping containers and packaging materials in case of damage.
  • Page 23: Warranty

    It is expressly understood and agreed that no officer, agent, salesman or employee of the manufacturer Intec (MANUFACTURER) has the authority to obligate the MANUFACTURER by any terms, stipulations, or conditions not herein expressed; that all previous representations and agreements, either verbal or written, referring to the machinery and equipment, which is the subject of this Warranty, are hereby superseded and canceled, and that there are no promises or agreements outside of the Warranty agreement.
  • Page 24: Certifications

    Instruction Manual Certifications T: 303-833-6644 800-666-1611 www.inteccorp.com Original Language - English...

This manual is also suitable for:

Turbo force hpmax