Intec FORCE 5150 Instruction Manual

Truck / trailer mount blowing machine

Advertisement

Quick Links

Instruction Manual
Insulation blowing machine
Original Language – English
Intec — 4040 Kodiak Court, Frederick, CO 80504 USA
T: 303-833-6644
Web: www.inteccorp.com
Email: info@inteccorp.com
T: 800-666-1611
Rev Date: 20181202

Advertisement

Table of Contents
loading

Summary of Contents for Intec FORCE 5150

  • Page 1 Instruction Manual Insulation blowing machine Original Language – English Intec — 4040 Kodiak Court, Frederick, CO 80504 USA T: 303-833-6644 Web: www.inteccorp.com Email: info@inteccorp.com T: 800-666-1611 Rev Date: 20181202...
  • Page 2 Engineered for High Productivity and Built-to-Last for High Value Generation. At Intec, we take pride in making your job as easy and profitable as possible. The right system for your needs: Intec strives to provide you with the best combination of portability, functionality, and installation versatility to surpass your desired success.
  • Page 3: Table Of Contents

    SYMBOLS ....................3 SAFETY FIRST ....................3 HOW THE SYSTEM WORKS ................. 4 System Set-Up: ..............................7 System Operation: ..............................9 Reprogramming Intec’s Long Range Transmission wireless remote ................10 MAINTENANCE .................... 11 TROUBLESHOOTING ..................13 SPECIFICATIONS…………………………………………………………………………………………………………….………….18 ELECTRICAL DRAWINGS ................... 19 MAKING A CLAIM FOR DAMAGE OR LOSS ...............
  • Page 4: Symbols

    Instruction Manual Symbols SYMBOL SYMBOL MEANING Indicates an imminently hazardous situation, which, if not avoided, Danger will result in death or serious injury. Indicates a potentially hazardous situation, which, if not avoided, Warning could result in death or serious injury. Indicates a potentially hazardous situation, which, if not avoided, Caution may result in minor or moderate injury.
  • Page 5: How The System Works

    Instruction Manual How the System Works OVERVIEW: Cellulose, Fiberglass, or Stone Wool insulation is loaded into the hopper. The agitation system is the first step in processing the insulation while moving towards the airlock column. Once in the column, insulation is processed additionally by the shredder bar. It then moves through the slide gate and into the airlock where the insulation is fed into the airstream created by the blower system.
  • Page 6 HONDA engine is appropriately cooled. The clean air from outside also prevents fibrous particles from being pulled into your engine’s cooling fins. Utilize Intec’s Air Inlet mounting plates to attached the hose coming from machine to fresh air. NOTE: Never run engine w/out the air inlet hose attached. Doing so will draw insulation into your engine’s cooling fins which will drastically reduce the life of your engine.
  • Page 7 Airlock: The airlock transfers the insulation from the agitation system into the airstream without coming into contact with the blowers. Insulation is discharged from the airlock into the hose. Urethane Airlock Seals: Your FORCE 5150 includes Intec’s proprietary urethane airlock seals for long lasting effectiveness. Proper airlock sealing allows for high production rates and high pressures for effective wall fill applications.
  • Page 8: System Set-Up

    Instruction Manual Quick Access Airlock Door: By removing six bolts, the Quick Access Airlock Door can be opened on its hinge to enable quick change of the airlock seals to ensure appropriate air sealing and peak production. Set up and Operation System Set-Up: INITIAL OPERATION During initial operation, install the fresh air inlet for the HONDA GX390.
  • Page 9 Instruction Manual Once mounted and hardware is tightened, you are ready to fasten the open side of the Fresh Air Inlet to the 10” diameter hose. Upon completion, you will now have fresh, clean air from outside your vehicle used to cool the HONDA engine.
  • Page 10: System Operation

    REMOTE QUICK DISCONNECT female connector. Note: Unplug the wired remote when not using the wire remote to operate the FORCE 5150. When unplugging, pull the metal tab back and turn ¼ turn, then remove male end from the REMOTE QUICK DISCONNECT female connector.
  • Page 11: Reprogramming Intec's Long Range Transmission Wireless Remote

     VARIABLE SPEED is in the off position, and  AUXILIARY BLOWER is in the ON position. 3. Load Insulation -- Remove packaging material from around insulation and load into hopper. Reprogramming Intec’s Long Range Transmission wireless remote Transmitter 1. Get to the underside of transmitter.
  • Page 12: Maintenance

    2. Clean engine air filter weekly. 3. Run engine at full throttle for appropriate operation of the FORCE 5150 blowing machine. Cleaning Clean the interior and exterior of the machine weekly by wiping with a rag and/or blowing with compressed air;...
  • Page 13 To tighten the generator’s belt, simply loosen each of the four bolts holding the generator to the FORCE 5150’s frame, push the generator in the direction away from the HONDA motor to tension the belt. When the belt has approximately ½”...
  • Page 14: Troubleshooting

    Auxiliary Blower switch is OFF. Place auxiliary blower switch into the ON position. Hose may be disconnected Contact Intec for appropriate from one-way valve to blower. troubleshooting. Worn brushes in blower motor. Have a qualified technician replace blower motor.
  • Page 15 Instruction Manual Problem Likely Cause Remedy Machine is on, yet no material Slide gate is closed. Open slide gate. comes out of hose. Insulation blockage in hose. Turn system off, remove hose and clear blockage. Blower is off. Turn blower on. Air pocket in hopper is Shut HONDA, press in E-Stop.
  • Page 16 This allows the machine to act as a source to gather the radio frequency waves and enhances reception). Install the optional antenna extender. Contact Intec for details. Transmitter out of range from Move closer to system. Blower and agitator continue to receiver.
  • Page 17: Specifications

    Instruction Manual Specifications Weight FORCE 5150 825 lbs; 375 kg Hopper size 31 cubic feet Blowers – Quantity = 2 115 VAC, 13.4 amp, two stage for each blower Motor HONDA GX390 with electric start T: 303-833-6644 800-666-1611 www.inteccorp.com Original Language - English...
  • Page 18: Electrical Drawings

    Instruction Manual Electrical Drawings T: 303-833-6644 800-666-1611 www.inteccorp.com Original Language - English...
  • Page 19: Making A Claim For Damage Or Loss

    Instruction Manual Making a Claim for Damage or Loss Your Intec products were carefully packed and thoroughly inspected before leaving our factory. We understand that damage to or defects with your system may unfortunately occur. Please inspect your shipment carefully upon arrival and save the shipping containers and packaging materials in case of damage.
  • Page 20: Warranty

    It is expressly understood and agreed that no officer, agent, salesman or employee of the manufacturer Intec (MANUFACTURER) has the authority to obligate the MANUFACTURER by any terms, stipulations, or conditions not herein expressed; that all previous representations and agreements, either verbal or written, referring to the machinery and equipment, which is the subject of this Warranty, are hereby superseded and canceled, and that there are no promises or agreements outside of the Warranty agreement.

Table of Contents