Circuit And Network Failure Recovery Mode; Figure 7-3. Circuit And Network Failure Recovery Mode - ADTRAN MX2800 M13 User Manual

Adtran network adapter user manual mx2800 m13
Table of Contents

Advertisement

MX2800 M13 Multiplexer User Manual
Table 7-1. Configuration Requirements for Circuit Recovery (Continued)
Config > Network Interface > Min. Switching Period
Config > T1/E1 Interface > T1/E1 Circuit Protection
Config > T1/E1 Interface > XCV Threshold
*.
This is a critical alarm only when Inactive Card is not installed or is not working.
4.

CIRCUIT AND NETWORK FAILURE RECOVERY MODE

In this mode, two controller cards are installed and connected to two individual DS3 lines. This is the most
complete mode of redundancy. In this mode, the primary controller card is connected to the primary DS3
line and the secondary controller card is connected to the secondary DS3 line. The primary card and line
actively transmit data, while the other card and line stand by ready to take over if the first card and line fail.
A feature of the MX2800 is its ability to internally re-route the network connection if a controller card and
the opposite network connection fail. For example, in the illustration given in
failed DS3 A is connected to healthy Card A and healthy DS3 B is connected to failed Card B. In a case
like this, the MX2800 is able to automatically re-route DS3 B to Card A.
The configuration requirements for this mode are the same as the ones given for
Mode
on page 7-2 except for the Network Protection setting, which must be set to Enable.
61200290L1-1G

Figure 7-3. Circuit and Network Failure Recovery Mode

Circuit and Network Redundancy, Section 7
10 seconds
Enable all or select theT1/E1s that redundant
switching should occur on.
1E-3
Figure 7-3
Circuit Failure Recovery
on page 7-3,
7-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents