ADTRAN MX2800 M13 User Manual page 139

Adtran network adapter user manual mx2800 m13
Table of Contents

Advertisement

Notification
AID
Code
404 (PS A)
MN
REPT
ALM
405 (PS B)
EQPT
404 (PS A)
MN
405 (PS B)
404 (PS A)
MJ
405 (PS B)
404 (PS A)
MN
405 (PS B)
404 (PS A)
MN
405 (PS B)
Table 9-3. MX2800 Alarm Events (Continued)
Condition
Service
Location
Type
Affecting
PWR-5
NSA
NEND
HITEMP
NSA
NEND
HITEMP
NSA
NEND
PWR-48
NSA
NEND
PROTNA
NSA
NEND
Description
Recommended Action
Power Supply Low
Replace the failed power supply. Use the aid of the alarm to
identify the card.
Power Supply Temp High
Reduce the temperature of the MX2800's operating environment
or provide better ventilation.
Power Supply Temp Critical
Reduce the temperature of the MX2800's operating environment
or provide better ventilation.
Power Supply Source
Check the –48 volt input indicated by the AID for a blown fuse
or disconnected/incorrect wiring.
Failure
Power Supply Card Removed
Check to see if card was removed by on-site personnel.