ADTRAN MX2800 M13 User Manual page 146

Adtran network adapter user manual mx2800 m13
Table of Contents

Advertisement

Section 9, Transaction Language 1 (TL1)
Table 9-6. TL1 Editing Data Dictionary for DS3 (Continued)
Keyword
FMT
LINELEN
RMTLPBK
SYSCARDARLY
SYSCARDBRLY
SYSCARDCOMMRLY
SYSCARDRLY
TMG
9-22
Type
Domain
ENUM
One of the following:
• CBIT
• M13
ENUM
One of the following:
• LONG
• SHORT
ENUM
One of the following:
• DISABLE
• EITHER
• FEAC
• CBIT
Y/N
Y or [N]
Y/N
Y or [N]
Y/N
Y or [N]
Y/N
Y or [N]
ENUM
One of the following:
• LPD
• INT
MX2800 M13 Multiplexer User Manual
Description
Sets framing format to match the format of
the receive signal at the network interface
• The framing format s set to CBIT
• The framing format is set to M13
Identifies Network DS3 line length
• LONG - exceeds 50 feet.
• SHORT - less than 50 feet.
Indicates whether the unit will respond to
remote loopbacks over FEAC, CBIT,
EITHER, or if remote loopbacks are disabled
• DISABLE - do not respond
• EITHER - respond over either FEAC or
CBIT
• FEAC - respond over FEAC
• CBIT - respond over CBIT
Identifies status of System Controller Card A
alarm relay
• Yes (Y) - enables alarm
• No (N) - disables alarm
Identifies status of System Controller Card B
alarm relay
• Yes (Y) - enables alarm
• No (N) - disables alarm
Identifies status of System Communication
Fail alarm relay
• Yes (Y) - enables alarm
• No (N) - disables alarm
Identifies status of System Controller Card
alarm relay
• Yes (Y) - enables alarm
• No (N) - disables alarm
Identifies timing supply for the DS3
• LPD - loop timed
• INT - internal timing source
61200290L1-1G

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents