3. From the firmware selection menu, using the arrow keys, select the entry "Intel <R> Rapid
Storage Technology" and confirm your selection.
4. Select "Create RAID Volume".
5. In the next window, enter a name for the RAID system.
6. Select "RAID Level" and select "RAID1" or "RAID5" in the following selection window,
depending on which RAID system you want to set up.
A list of available drives is displayed.
7. Under "Select Disks" select the drives ① that you want to integrate into your RAID system
and confirm your selection.
– The integrated drive is given a check mark in the list ②.
– You can find the assignment of the drive to the mounting location in the drive bay in
8. Select "Create Volume".
In the next window, the details of the RAID system (RAID volume) that you have just set
up are displayed.
The onboard RAID system is set up.
9. To exit the firmware settings, press the <F4> button (Save & Exit) and confirm the
subsequent dialog with <Y>.
Setting up Onboard RAID system "Intel® Rapid Storage Technology"
1. Select "Start > Programs > Start > Intel".
2. Select the "Manage" tab.
Information on setting up a RAID system with "Intel® Rapid Storage Technology" is
available in the documentation or software help.
5.4.4.2
Monitoring the onboard RAID system with "Intel® Rapid Storage Technology"
Open software for monitoring the "Intel® Rapid Storage Technology" onboard RAID system
1. Select "Start > Programs > Start > Intel".
Operating Instructions, 01/2021, A5E43920357-AA
front of the drive model designation, see ③.
Operating the device
5.4 Onboard RAID system