Power ratings
Item
Efficiency (typical)
Input
Voltage (See note 1.)
Frequency (See note 1.)
Current
100-V input
200-V input
Power factor
Harmonic current emissions
Leakage current
100-V input
200-V input
Inrush current
100-V input
(See note 2.)
200-V input
Output
Voltage adjustment range
(See note 3.)
Ripple
Input variation influence
Load variation influence
(rated input voltage)
Temperature variation influence
Startup time (See note 2.)
Hold time (See note 2.)
Addition-
Overload protection (See note 2.)
al func-
Overvoltage protection
tions
(See notes 2 and 4.)
Output voltage indication (See note 5.) No
Output current indication (See note 5.) No
Peak-hold current indication
(See note 5.)
Maintenance forecast monitor indica-
tion (See note 5.)
Maintenance forecast monitor output No
Total run time monitor indication
(See note 5.)
Total run time monitor output
(See note 5.)
Undervoltage alarm indication
(See note 5.)
Undervoltage alarm output terminals
Parallel operation
Series operation
Other
Operating ambient temperature
Storage temperature
Operating ambient humidity
Dielectric strength
Insulation resistance
Vibration resistance
Shock resistance
Output indicator
EMI
Conducted
Emissions
Radiated
Emissions
EMS
Approved standards
SEMI
Weight
Note: Refer to page 5 for notes 1 to 11.
http://www.ia.omron.com/
240 W
Type
Standard
Maintenance
forecast monitor
80% min.
100 to 240 VAC (85 to 264 VAC)
50/60 Hz (47 to 63 Hz)
3.8 A max.
2.0 A max.
0.95 min.
Conforms to EN61000-3-2
0.5 mA max.
1.0 mA max.
25 A max. (for a cold start at 25°C)
50 A max. (for a cold start at 25°C)
±10% (with V.ADJ) (guaranteed)
2.0% (p-p) max. (at rated input/output voltage)
0.5% max. (at 85 to 264 VAC input, 100% load)
1.5% max. (with rated input, 0 to 100% load)
0.05%/°C max.
1,000 ms max. (at rated input/output voltage)
20 ms min. (at rated input/output voltage)
105% to 160% of rated load current, voltage drop, automatic reset
Yes
Yes (selectable) (See note 6.)
Yes (selectable) (See note 7.)
No
Yes (selectable) (See note 8.)
No
Yes
(selectable)
Yes (transistor out-
put), 30 VDC max.,
50 mA max.
(See note 9.)
No
No
No
Yes (selectable)
No
Yes (transistor output), 30 VDC max., 50 mA
max.
(See note 9.)
No
Yes for up to 2 Power Supplies (with external diode)
Refer to the derating curve in Engineering Data (60-W, 90-W, 120-W, 180-W, 240-W, and 480-W Models). (with no icing or condensation)
−25 to 65°C
25% to 85% (Storage humidity: 25% to 90%)
3.0 kVAC for 1 min. (between all inputs and outputs/ alarm outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)
1.0 kVAC for 1 min. (between all outputs/ alarm outputs and PE terminals; detection current: 240 W, 20 mA/ 480 W, 30 mA)
500 VAC for 1 min. (between all outputs and alarm outputs; detection current: 20 mA)
100 MΩ min. (between all outputs/ alarm outputs and all inputs/ PE terminals) at 500 VDC
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
10 to 150 Hz, 0.35-mm single amplitude (5 G max.) for 80 min each in X, Y, and Z directions: 240 W
10 to 150 Hz, 0.35-mm single amplitude (3 G max.) for 80 min each in X, Y, and Z directions: 480 W
2
150 m/s
, 3 times each in ±X, ±Y, and ±Z directions
Yes (color: green)
Conforms to EN61204-3 EN55011 Class A and based on FCC Class
A
Conforms to EN61204-3 EN55011 Class B (See note 10.)
Conforms to EN61204-3 EN55011 Class A
Conforms to EN61204-3 EN55011 Class B (See note 10.)
Conforms to EN61204-3 high severity levels
UL: UL508 (Listing), UL60950-1
cUL: CSA C22.2 No.14,
cUR: CSA C22.2 No. 60950-1,
EN/VDE: EN50178 (=VDE0160),
SELV (EN60950/UL50178/UL60950-1)
According to VDE0106/P100, IP20
F47-0200 (200-VAC input)
1,150 g max.
Total run time
Standard
monitor
83% min.
7.4 A max.
3.9 A max.
−10% to 15% (with V.ADJ) (guaranteed)
No
No
No
No
No
Yes
No
(selectable)
Yes (transistor out-
No
put), 30 VDC max.,
50 mA max.
(See note 9.)
No
No
Conforms to EN61204-3 EN55011 Class A and based on FCC Class
A
Conforms to EN61204-3 EN55011 Class B (See note 11.)
Conforms to EN61204-3 EN55011 Class A
Conforms to EN61204-3 EN55011 Class B (See note 11.)
UL: UL508 (Listing), UL60950-1
cUL: CSA C22.2 No.107.1,
cUR: CSA C22.2 No. 60950-1,
EN/VDE: EN50178 (=VDE0160),
EN60950-1 (VDE0805 Teil 1)
SELV (EN60950/UL50178/UL60950-1)
According to VDE0106/P100, IP20
1,700 g max.
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
S8VS
480 W
Maintenance
Total run time
forecast monitor
monitor
Yes (selectable) (See note 6.)
Yes (selectable) (See note 7.)
Yes (selectable) (See note 8.)
Yes (selectable)
No
Yes (transistor out-
No
put), 30 VDC max.,
50 mA max.
Yes
(selectable)
Yes (transistor out-
put), 30 VDC max.,
50 mA max.
(See note 9.)
Yes (selectable)
Yes (transistor output), 30 VDC max., 50 mA
max.
(See note 9.)
7