Safety Precautions - Omron S8VS Series Manual

Hide thumbs Also See for S8VS Series:
Table of Contents

Advertisement

Safety Precautions

!CAUTION
Minor electric shock, fire, or Product failure may
occasionally occur. Do not disassemble, modify, or repair
the Product or touch the interior of the Product.
Minor burns may occasionally occur. Do not touch the
Product while power is being supplied or immediately
after power is turned OFF.
Fire may occasionally occur. Tighten terminal screws to
the specified torque (15- and 30-W models: 0.8 to
1.0 N·m/60-, 90-,120-, 180-, 240-, and 480-W models:
1.08 N·m).
Minor injury due to electric shock may occasionally occur.
Do not touch the terminals while power is being supplied.
Always close the terminal cover after wiring.
Minor electric shock, fire, or Product failure may
occasionally occur. Do not allow any pieces of metal or
conductors or any clippings or cuttings resulting from
installation work to enter the Product.
■ Precautions for Safe Use
Mounting
Take adequate measures to ensure proper heat dissipation to
increase the long-term reliability of the Product. Be sure to allow
convection in the atmosphere around devices when mounting. Do
not use in locations where the ambient temperature exceeds the
range of the derating curve.
When cutting out holes for mounting, make sure that cuttings do not
enter the interior of the Products.
*1
*2
*1
(15-W and 30-W Models)
Improper mounting will interfere with heat dissipation and may
occasionally result in deterioration or damage of internal parts. Use
the Product within the derating curve for the mounting direction that
is used.
Use a mounting bracket when the Product is mounted facing
horizontally.
Heat dissipation will be adversely affected. When the Product is
mounted facing horizontally, always place the side with the label
facing upward.
Always provide a space of 20 mm even when mounting horizontal or
facing horizontal. If a space of 20 mm is not available, reduce the
temperatures given in the derating curve on page 11 by 5°C and
provide a space of at least 10 mm.
(60-W, 90-W, 120-W, 180-W, 240-W, and 480-W
Models)
Improper mounting will interfere with heat dissipation and may
occasionally result in deterioration or damage of internal parts. Use
the standard mounting method only.
The internal parts may occasionally deteriorate and be broken due to
adverse heat radiation. Do not loosen the screw on the side face of
the main body.
http://www.ia.omron.com/
*1. Convection of air
*2. 20 mm min.
Wiring
Connect the ground completely. A protective earthing terminal
stipulated in safety standards is used. Electric shock or malfunction
may occur if the ground is not connected completely.
Minor fire may possibly occur. Ensure that input and output terminals
are wired correctly.
Do not apply more than 100-N force to the terminal block when
tightening it.
Be sure to remove the sheet covering the Product for machining
before power-ON so that it does not interfere with heat dissipation.
Use the following material for the wires to be connected to the S8VS
to prevent smoking or ignition caused by abnormal loads.
Recommended Wire Type
15-W and 30-W Models
Model
Stranded wire
S8VS-03005
AWG18 to 14
(0.9 to 2.0 mm
Other models
AWG20 to 14
(0.5 to 2.0 mm
60-W, 90-W, 120-W, 180-W, 240-W, and 480-W Models
Model
Recommended wire size
For screw terminal
S8VS-06024@
AWG14 to 20
(Cross section 0.517 to
2
2.081 mm
)
S8VS-09024@@
AWG14 to 18
S8VS-12024@@
(Cross section 0.823 to
S8VS-18024@@
2
2.081 mm
)
S8VS-24024@@
S8VS-48024@
Input terminals
AWG 14 to 16
(Cross section 1,309 to
2
2,081 mm
)
Output terminal
(see note.)
AWG 14
(Cross section 2,081 mm
Note: The rated current for output terminals is 10 A per terminal. Be
sure to use multiple terminals simultaneously for current that
exceeds the terminal rating.
Installation Environment
Do not use the Power Supply in locations subject to shocks or
vibrations. In particular, install the Power Supply as far away as
possible from contactors or other devices that are a vibration source.
Install the Power Supply well away from any sources of strong,
high-frequency noise and surge.
Operating Life
The life of a Power Supply is determined by the life of the electrolytic
capacitors used inside. Here, Arrhenius Law applies, i.e., the life will
be cut in half for each rise of 10°C or the life will be doubled for each
drop of 10°C. The life of the Power Supply can thus be increased by
reducing its internal temperature.
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
S8VS
Solid wire
AWG18 to 16
2
2
)
(0.9 to 1.1 mm
)
AWG20 to 16
2
2
)
(0.5 to 1.1 mm
)
For alarm output
terminal
---
AWG18 to 28
(Cross section 0.081
2
to 0.823 mm
)
(Wires to be stripped:
9 to 10 mm)
2
)