Dmx Control - Magicfx FLAMEBLAZER User And Installation Manual

Hide thumbs Also See for FLAMEBLAZER:
Table of Contents

Advertisement

1.6

DMX CONTROL

The MAGICFX FLAMEBLAZER
address:
DMX address
Enable address
Start address
The enable address cannot be the same as the operational address. Operating of
these addresses results in the following:
DMX address
Enable address
Start address
(Effect trigger)
NOTICE
NOTICE
is controlled with 1 enable address and 1 operational
®
Address range
1 - 512
1 - 512
DMX Value (decimal)
0
99
100
154
155
255
0
199
200
255
The maximum continuous duration of the effect is 5 seconds. After
this period the effect will stop automatically. To start the effect
again you must disable and re-enable the Effect trigger.
Always plug in a DMX Terminator into the DMX output of the final
unit in the control sequence. Using a DMX Terminator improves
signal reliability.
MAGICFX FLAMEBLAZER
Control
Device enable/disable
Effect trigger
Result
Device disabled
Device enabled
Device disabled
No output
Output effect
Operation of the DMX addresses
— User and Installation Manual
®
DMX addresses
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfx1401

Table of Contents