TROUBLESHOOTING

Code
Meaning
018
Pressure keeps
dropping.
020
Pressure Sensor
Failure.
121
Orientation of
device out of
safe bounds.
Always contact MAGIC FX if any malfunctions or errors occur that cannot be solved
with the instructions as described in this manual.
5

MAINTENANCE

To achieve the maximum service life of the MAGICFX FLAMEBLAZER
regularly clean the MAGICFX FLAMEBLAZER
Before conducting any maintenance ensure the machine is switched off and
disconnected from a power source and the machine is not hot from recently being
used. Always use personal protective equipment such as safety glasses and gloves
when handling fuels.
Maintenance task
General clean.
Inspect and clean
nozzles.
34
MAGICFX FLAMEBLAZER
Solution
• Make sure the fuel can is not empty.
• If the problem is not solved contact MAGIC FX.
• Contact MAGIC FX.
• Keep the device within previously described safe
bounds.
Activity
Remove any foreign objects from burn chamber before every
use being careful not to move or damage the spark ignition
probes. Remove any dust or dirt from hose connections with a
non-abrasive damp cloth.
Remove nozzle with MAGICFX FLAMEBLAZER® Nozzle exchange
tool. Submerge nozzle in Isopropanol for minimum of 1 minute.
Remove from solution and when dry use compressed air to
blow through the nozzle in opposite direction of fuel. Before
inserting nozzle back into machine conduct a visual check of
the washer seal to make sure no damage to the soft material
and replace the washer seal if damaged.
— User and Installation Manual
®
and test if it is functioning correctly.
®
you must
®