3
If pyro is used, follow the next steps:
1.
Connect an arm cable to the arm in connector on the machine.
2.
Connect the other end of the arm cable to the MAGICFX
CONTROLLER.
3.
Connect the power cables to the 9-40 Vdc in pyro connector.
4.
Connect the other end of the power cables to the external low voltage
pyro controller (9-40 Vdc).
5.
Connect a power cable with a PowerCon TRUE1 female connector to a
220-250 Vac (50-60 Hz) power source.
6.
Connect the other end of the power cable to the power input. The
screen will light up.
7.
Use the display and buttons to set Pyro Input Control to ON.
9-40 Vdc +
POWER
ARM
NOTICE
30
MAGICFX FLAMEBLAZER
Only one MAGICFX
single connected system. Connecting more than one controller
with RJ45 Arm leads can cause damage to them.
PowerCon TRUE1 female
RJ45
When using the pyro Input Control method, make sure Pyro Input
Control is set to ON. The DMX signal LED will not light up.
— User and Installation Manual
®
FX-ARM CONTROLLER can be used in a
®
9-40 Vdc -
DMX IN
DMX OUT
POWER IN
POWER OUT
RJ45 IN
RJ45 OUT
FX-ARM
®