Inspect and clean
spark ignition
probes.
Contact MAGIC FX if the MAGICFX FLAMEBLAZER
Firmware updates can add additional features and fix bugs so regulalry check on
the website or with your MAGIC FX account manager to ensure you have the latest
version.
DANGER
Any foreign particles should be removed from the probes,
which can be cleaned with Isopropanol and a light abrasive
cloth. Ignition probes should not be adjusted from the factory
setting as this is critical to safe and reliable ignition. To check
they are in the correct position each pair of probes must have
a gap from tip to tip of 4 mm (+/-2 mm) and opposite probes
must have a gap from tip to tip of 16 mm (+2 mm). If they do
not have these gaps or are miss-aligned in anyway contact
MAGIC FX.
Do not replace parts yourself; always consult MAGIC FX if
necessary.