Connecting The Machine - Magicfx FLAMEBLAZER User And Installation Manual

Hide thumbs Also See for FLAMEBLAZER:
Table of Contents

Advertisement

3.5

CONNECTING THE MACHINE

1
Make sure the DMX or Pyro controller is disconnected from power or power
switch is disabled.
2
If DMX is used, follow the next steps:
1.
Connect an arm cable to the arm in connector on the machine.
2.
Connect the other end of the arm cable to the MAGICFX
CONTROLLER.
3.
Connect the female connector of a 5-pole DMX cable in the DMX input.
4.
Connect the other end of the DMX cable to the DMX controller.
5.
Connect a power cable with a PowerCon TRUE1 female connector to a
220-250 Vac (50-60 Hz) power source.
6.
Connect the other end of the power cable to the power input. The
screen will light up.
7.
Use the display and buttons or a RDM controller to assign DMX
addresses and check if the signal LED flashes (see Chapter 1). This
indicates the DMX signal is applied.
DMX
POWER
ARM
NOTICE
5-pole female
PowerCon TRUE1 female
RJ45
Make sure Pyro Input Control is set to OFF otherwise the DMX
signal LED will not flash, even when there is a DMX signal applied.
MAGICFX FLAMEBLAZER
DMX IN
DMX OUT
POWER IN
POWER OUT
RJ45 IN
RJ45 OUT