5
Carefully lower the MAGICFX FLAMEBLAZER® Nozzle exchange tool with nozzle
into the burn chamber until the nozzle locates into the bulkhead orifice. Rotate
anti-clockwise until a click is heard or felt to check the threads are aligned.
Make sure the tool is held vertical, continuous clockwise rotation will tighten the
nozzle into place.
NOTICE
CAUTION
CAUTION
22
MAGICFX FLAMEBLAZER
The nozzle quickly goes from loose to tight as the seal meets the
bulkhead and does not need to be tightened with excessive
force. 12 Nm is sufficient for a good seal.
Check there is no foreign objects or material in the bulkhead
orifice prior to inserting the nozzle as this can lead to blockages
or misfires resulting in a dangerous situation.
Cross-threading the nozzle into the bulkhead, under tightening or
not using a ring seal will cause a poor seal resulting in fuel leaks
in the burn chamber.