Summary of Contents for Oneida Air Systems Super DUST GORILLA
Page 1
2 HP Cyclonic Dust Collector Owners Manual T905 GORILLA Shown with optional *Models may bolt together Angle vary sligthly in Iron stand. appearance. Oneida Air Systems, Inc. 1001 West Fayette St., Syracuse, N.Y. 13204 Phone 1-800-732-4065 315-476-5151 Fax 315-476-5044 www.oneida-air.com...
Thank You for Choosing an Oneida Air Systems Product! OAS manufactures and sells dust collection equipment only. Our qualified technicians and sales staff are available 7:30am - 6:00pm EST Mon. - Thur. and 7:30am - 5:00pm EST Fri. to answer any questions concerning OAS products and dust collection. Call for ductwork design and ductwork quotes, including system pricing and shipping cost.
Check amperage draw during operation with all blast gates open. Make certain amperage is not outside operating limit indicated on motor plate! Warning If amperage is too high - shut down immediately! (See troubleshooting section.) 2HP Super Dust Gorilla Owners Manual O.A.S. 2005...
Accredited, independent lab tested. Bathed in teflon-like coating for easy dust release. Captures 99.9% of Test Material from 0.2 - 2 microns. 1. External Cartridge Filter Shown with optional Angle Iron Stand. 2HP Super Dust Gorilla Owners Manual O.A.S. 2005...
95 Sq. Ft. 24.5 Outlet - Can be rotated independent of the inlet. 6 2 Flex for 91 Min. Height 2 Collar drum Note: Check drum height, it will affect your bracket height. 2HP Super Dust Gorilla Owners Manual O.A.S. 2005...
Note: For cyclonic preseparation there must be an air tight seal between cyclone and dust container. Dust bin must be located vertically under cyclone, material drops down by gravity. 2HP Super Dust Gorilla Owners Manual O.A.S. 2005...
Material Cyclone Cone 3/8 Bolt / (2) Washers / Collector Serrated Nut per bolt hole on each side and back. Hose Clamp GORILLA Flex Hose Hose Clamp Dust Bin 2HP Super Dust Gorilla Owners Manual O.A.S. 2005...
56 to top of plate. Distance tor minimum mounting height. * Optional Mounting Direction Note: Please do not install an Oneida Dust Collection System alone. Competent assistance is advisable. Units are heavy! 2HP Super Dust Gorilla Owners Manual O.A.S. 2005...
If exhaust air is vented outside you must provide make up / return air. Flue gases (carbon monoxide) can be drawn into the shop from furnaces, water heaters or other appliances. Caution: Rotating blades! Keep hands clear. Keep people away from exhaust. 2HP Super Dust Gorilla Owners Manual O.A.S. 2005...
Use 12 gauge cord for the fan / blowers. Lubrication: The motor is supplied with pre-lubricated ball bearings, lubricated for the life of the bearing. Caution: Rotating Fan Blades! Keep objects clear of outlet. 2HP Super Dust Gorilla Owners Manual O.A.S. 2005...
Keep nozzle at least 6 from filter and keep your pressure down. Closer blasts may damage filter material. Rinse off INSIDE of filter. Let filter dry completely before reuse or keep a spare filter on hand. 2HP Super Dust Gorilla Owners Manual O.A.S. 2005...
(220v, CCW rotation) = Wire Nut (Tape & Insulate) *Starter will not operate at any other voltages. **Starter is shown configured for 1O but can also be used for 2hp, 3O motors. 2HP Super Dust Gorilla Owners Manual O.A.S. 2005...
Electrically ground all equipment and ducting. Static sparks can ignite wood dust. (Avoid using PVC drainpipe) Dont allow accumulation of layers of fine dust on horizontal surfaces. (Especially overhead lights, electrical boxes, and fuse panels which can ignite dust) Unplug unit before servicing or cleaning. 2HP Super Dust Gorilla Owners Manual O.A.S. 2005...
Oneida Air Systems shall be tried in the State of New York, County of Onondaga. Oneida Air Systems shall in no event be liable for death, injuries to persons or property or for incidental, contingent, special, or consequential damages arising from the use of our product.