  • Page 1 1.5 HP Cyclonic Dust Collector Owner’s Manual GORILLA *Models may vary sligthly in appearance. Oneida Air Systems, Inc. 1001 West Fayette St., Syracuse, N.Y. 13204 Phone 1-800-732-4065 315-476-5151 Fax 315-476-5044 www.oneida-air.com...
  • Page 2: Table Of Contents

    Thank You for Choosing an Oneida Air Systems Product! OAS manufactures and sells dust collection equipment only. Our qualified technicians and sales staff are available 7:30am - 6:00pm EST Mon. - Thur. and 7:30am - 5:00pm EST Fri. to answer any questions concerning OAS products and dust collection. Call for ductwork design and ductwork quotes, including system pricing and shipping cost.
  • Page 3: System Start-Up Information

    I. System Start-Up Information 1. Read the installation and maintenance instructions as well as the recommended safety practices in this manual. 2. Install Ductwork completely before operating collector: A.) Seal ductwork with silicone sealant or duct tape. B.) Have Dust Bin in place and sealed. 3.
  • Page 4: Commercial Configurations

    II. 1.5hp Dust Gorilla Configurations Caution: If exhaust air is vented outside you must provide make up / return air. Flue gases (carbon monoxide) can be drawn into the shop from furnaces, water heaters or other appliances. 1. External Cartridge Filter - Silencer Included with Filter Cartridge Filter Media 1 Pleated Cartridge Filter 26”...
  • Page 5: General Specifications & Fan Performance Curves

    III. General Specifications & Fan Performance Curves Height with Cyclone Inlet Weight without TEFC Dust Bin Diameter Diameter Dust Bin Motors Class B Approx. Wt. 110/220v 122 lbs. 85.5” 18” 6” 16 / 8 amps w/o drum or filter - Sleeve kit adds 7” (4” is minimum) - 35 gal.
  • Page 6: Dimensions

    IV. Dimensions For Minimum Mounting Heights w/ 35 Gal. Drum *Dimensions subject to slight variation in manufacturing. 85.5” 6” 72.8” 64” 56” 3” 28.5” 27.4” 45” Top View 1.5HP Dust Gorilla Owner’s Manual O.A.S. 2008...
  • Page 7: General Assembly

    V. General Assembly 1. BX1001805 - Motor Assembly 1.5hp Super Gorilla 2. RDZ180000 - (2) Ductmate Ring with Bolt 18 3. RGZ000000 - 25’ Gasket Material (4) 3/8” x 1” Bolts (8) 3/8” Washers 4. SX1001805 - Barrel 1.5hp Super Gorilla (4) 3/8”...
  • Page 8: Bracket Assembly

    VI. Bracket Assembly 1. You must determine the direction the fan outlet will point to proceed with this mounting assembly. The collector will seem 16” quieter if the outlet is aimed away from the area people tend to work. Slots in the brackets are .406” x 1.00” .406”...
  • Page 9: Filter Assembly

    VII. Filter Assembly External 26” Filter Assembly *Silencer Included. 1. Attach cartridge with hardware provided making sure gasket is attached. See Fig. 1 GORILLA 2. If Filter requires additional support. Use the plate at the Silencer top of the filter to support the filter assembly. Note: If filter cartridge is located away from the cyclone and motor, additional square-to-round connectors and pipe can be purchased.
  • Page 10: Filter Maintenance

    VIII. Filter Maintenance External Filter Cartridge Cleaning Intervals When unit is turned off, use compressed air to blow dust off from exterior of filter. Hold nozzle at least 6” away from filter pleats*. Do not remove bottom dust pan before or during the blow-off process! Let dust settle into dust pan.
  • Page 11: Directions For Cleaning External Filter

    IX. Directions for Cleaning External Filter All steps should be done with a dust mask and eye protection. The External Filter can be cleaned using the following methods: 1. Compressed air from outside. Blast air along pleats of the filter at about a 20 angle. Blast air out and away from you or anyone in the general area.
  • Page 12: Fan / Blower Wiring Diagram

    X. 1.5 Hp Wiring Diagram Use wiring diagram on motor plate if different from below. Wiring should always be done by a licensed electrician! - Electrically insulate all connections. - For counter-clockwise rotation, looking from top of motor down. High Voltage 208 - 230V / 8.5 Amps Low Voltage 115V / 17 Amps Power Line 1* Power Line 1...
  • Page 13: Troubleshooting

    XI. Troubleshooting Unplug unit before servicing or cleaning. 1.5HP Dust Gorilla Owner’s Manual O.A.S. 2008...
  • Page 14: Fire Hazards

    XII. Fire Hazards - Read Before Installing and Operating Oneida Collectors are designed for WOOD DUST only!! Wood shaping and cutting processes generate wood chips, shavings, and dust. These materials are considered combustible. Air borne wood dust below 420 microns in size (.017 of an inch) in certain concentration ranges when ignited can deflagrate (burn quickly).
  • Page 15: Terms And Conditions

    Oneida Air Systems shall be tried in the State of New York, County of Onondaga. Oneida Air Systems shall in no event be liable for death, injuries to persons or property or for incidental, contingent, special, or consequential damages arising from the use of our product.
  • Page 16: Stand Assembly

    XIV. Stand Assembly - STG018035 24” 19” 19” 24” 24” 56” 19” 19” Washer Bolt Stand 1.5HP Dust Gorilla Owner’s Manual O.A.S. 2008...
  • Page 17: Accessories

    XV. Accessories Bolt Together Angle Iron Stand STG018035 - 35 gal. Stand STG018055 - 55 gal. Stand Kit Contents: Filter Efficiency Gauge FXK000000 INCHES W.C. This easy to read gauge takes the guesswork out of knowing when your filters need Gauge Bracket to be cleaned and tells you how much pressure is backed up behind your filters.
  • Page 18: Optional - Filter Gauge Mounting Instructions

    Optional - XVI. Filter Efficiency Gauge Mounting Instructions Rectangular Plenum Can be attached INCHES W.C. up to 8’ away. Mounting Instructions 1. Mount brass static pressure tube in plenum with tip pointed into the air stream. Use mounting bracket and sheet metal screws if interior of plenum is not accessible.