Oneida Air Systems Dust Gorilla Pro Owner's Manual

Oneida Air Systems Dust Gorilla Pro Owner's Manual

With smart boost 3 hp/5 hp
Hide thumbs Also See for Dust Gorilla Pro:

Advertisement

OWNER'S MANUAL
U.S. Patent: #8491685
U.S. Patent: #9370740
U.S. Patent: #8514090
U.S. Patent: #8496719
U.S. Patent: #7247180
Rev: 12/03/2018
Appearance may vary slightly
Dust Gorilla Pro
Dust Collector
with SMART Boost
# XGK030035
# XGK030055
# XGK050035
# XGK050055
Doc. #ZBM000104
3 HP/5 HP

Advertisement

Table of Contents
loading

Summary of Contents for Oneida Air Systems Dust Gorilla Pro

  • Page 1 OWNER’S MANUAL Dust Gorilla Pro Dust Collector with SMART Boost 3 HP/5 HP # XGK030035 # XGK030055 # XGK050035 U.S. Patent: #8491685 # XGK050055 U.S. Patent: #9370740 U.S. Patent: #8514090 U.S. Patent: #8496719 U.S. Patent: #7247180 Appearance may vary slightly Rev: 12/03/2018 Doc.
  • Page 3: Table Of Contents

    Table of Contents System Start-Up Information System Specifications for 3 HP System Specifications for 5 HP System Dimensions for 35 Gallon Drum System Dimensions for 55 Gallon Drum System Contents Assembly Instructions Maintenance Troubleshooting Recommended Accessories Warranty Information Notes oneida-air.com...
  • Page 4: System Start-Up Information

    5. Check amperage draw on motor with all gates open. Current draw should not exceed maximum motor amperage as stated on motor plate. (Oneida Air Systems is not responsible for damage to motors caused by improper installation, wiring or failure to follow these directions).
  • Page 5 System Start-Up Information (Continued) d. NFPA664 Code book, “Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities”, applies to woodworking operations that occupy areas of more than 5,000 sq. ft. or to areas where dust producing equipment requires an aggregate dust collection flow rate of more than 1,500 cfm (cubic feet per minute).
  • Page 6: System Specifications For 3 Hp

    99.97% @ 0.3 microns Filter Surface Area 110 Sq. Ft. SYSTEM DIMENSIONS AND CONSTRUC TION Barrel/Cyclone Body Heavy-gauge cold-rolled steel Inlet 7" Diameter Overall Height (with 35 Gallon Drum) 94" Overall Height (with 55 Gallon Drum) 106" Oneida Air Systems...
  • Page 7: System Specifications For 5 Hp

    System Specifications for 5 HP OPER ATION Fan Rating (Free Fan) 5 HP: 3,250 CFM Fan Rating (with Cyclone & Filter) 5 HP: 1,625 CFM at 3" WC Maximum Suction Rating 5 HP: 23” WC MOTOR AND ELEC TRIC AL Motor Type U.S.
  • Page 8: System Dimensions For 35 Gallon Drum

    219 mm 18" 457 mm 30" 762 mm 94" 2,388 mm 16" 406 mm 56" 75.5" 66.5" 1,422 mm 1918 mm 1,689 mm 36" 914 mm 25" 635 mm 8" 203 mm 27" 686 mm 30" 762 mm Oneida Air Systems...
  • Page 9: System Dimensions For 55 Gallon Drum

    System Dimensions for 55 Gallon Drum Nominal dimensions shown with a 55 gallon drum. Dimensions subject to slight variations in manufacturing. Top View 48" 219 mm 18" 457 mm 30" 762 mm 106" 2,,692 mm 16" 406 mm 68" 87.5" 78.5"...
  • Page 10: System Contents

    • 7/16" Wrench • 1/2" Deep Impact Socket • Razor Knife • 7/16" Socket Wrench • 8' Ladder • Diagonal Cutters • 1/2" Wrench • Tape Ruler • Spirit Level • 1/2" Socket Wrench • Scissors • Anchor Screws Oneida Air Systems...
  • Page 11 System Contents (Continued) Note: Sent out attached to the Motor Assembly (A) oneida-air.com...
  • Page 12: Assembly Instructions

    Otherwise you will not get the seal needed for complete dust collection! FIG. 1 10 Oneida Air Systems...
  • Page 13 Assembly Instructions (Continued) Apply Gasket (K1) making sure that there is no gap where the ends meet: a. Apply to the top flange of the Cone (D) Top View inside the bolt holes [FIG. 2a]. b. Apply to the top rim of the Barrel (C) outside of the bolt holes [FIG.
  • Page 14 Secure both components to the stand using twelve Hex Head Bolts (K5) and twenty-four 5/16" Flat Washers (K3), and twelve Whiz-Lock Nuts (K6). [FIG. 4b] Note: Tighten firmly but do not over compress the FIG. 4b gasket. FIG. 4a 12 Oneida Air Systems...
  • Page 15 Assembly Instructions (Continued) Lift the Fan Housing (B) onto the Barrel (C), making sure it is oriented so that the molded “UP” text is visible. Align the housing’s holes with the holes in the barrel and keep in mind the direction you want your outlet to face.
  • Page 16 Attach the flat top of the Support Brace (L) to the lower corners of the Filter Plenum Elbow (J1) with two 3/8-16" x 1.25" Hex Head Bolts (K9), two 3/8" Flat Washers (K8), and two Whiz- Lock Nuts (K11). FIG. 9 14 Oneida Air Systems...
  • Page 17 Assembly Instructions (Continued) Install other end of the Support Brace (L) to the flange of the Barrel (C) using the hardware installed in Step 5. Note: The hardware removed will depend on your outlet’s orientation. FIG. 10 Insert the Drop-In Silencer (J3) into the top of the Filter (I) as shown in [FIG.
  • Page 18 Flex Hose (F) using a razor knife and diagonal cutter to cut through the clear lining and reinforcing wire. Note: Be careful to only remove 0.5” at a time so as not to over trim. FIG. 13 16 Oneida Air Systems...
  • Page 19 Assembly Instructions (Continued) To ground the filter, attach the ring terminal on the braided ground wire from the Motor Assembly (A) to a bolt on the filter plate, under the nut, then attach the alligator clip to the filter’s cage [FIG. 15]. Note: If you need to extend the wire, you can use any 16 gauge copper stranded wire and connect with wire nuts...
  • Page 20: Maintenance

    Corrosion Severe Dirt; > 122° F (50° C) Extreme Abrasive Dust; or Class H Insulation* Corrosion < -22° F (-30° C)** Temperature * Special HIGH temperature grease is recommended ** Special LOW temperature grease is recommended 18 Oneida Air Systems...
  • Page 21: Troubleshooting

    Clean filter more often with compressed air.  If you continue to experience difficulty with your dust collector, call Oneida Air Systems’ Customer Service Department at 1-866-387-8822 or email support@oneida-air.com. oneida-air.com...
  • Page 22: Recommended Accessories

    RF Remote Control Key Fob #AMR000000 • Sends long range wireless signal via radio frequency. • Works at long distances and even through walls! • Compatible only with systems that include a magnetic motor starter control box. 20 Oneida Air Systems...
  • Page 23 Universal Drum Dolly #SDD990000 • Fits nearly any cylindrical waste bin sold by Oneida Air Systems. • Includes five 2" non-marking caster wheels (3 non-locking, 2 locking). • Requires Leg Extension Kit (Item #STZ212301) if used with a stand mounted system.
  • Page 24: Warranty Information

    In no event shall Oneida Air Systems’ liability under this warranty exceed the purchase price paid for the product and any legal actions brought against Oneida Air Systems shall be tried in the State of New York, County of Onondaga.
  • Page 25: Notes

    Notes oneida-air.com...
  • Page 26 Regardless of where you purchased your system, if you have any questions or issues with missing / damaged parts, please call Oneida Air Systems first to let us help resolve your problem. We fully stand behind the quality of our product and place the utmost value on our customer’s opinion.

Table of Contents