  • Page 1 2 HP Commercial Cyclonic Dust Collector Owner’s Manual Oneida Air Systems, Inc. 1001 West Fayette St., Syracuse, N.Y. 13204 Phone 1-800-732-4065 315-476-5151 Fax 315-476-5044 www.oneida-air.com...
  • Page 3: System Start-Up Information

    I. System Start-Up Information Caution The Direct Drive Fan / Blower makes the system top heavy! Use extreme care when setting the unit up! Warning Do not operate Fan / Blower unless Cyclone and Dust Bin are in place. Motor will over heat! Warning Check amperage draw during operation with all blast gates open.
  • Page 4 II. 2hp Commercial Configurations 1. No Filter - Vent Outside - Caution: 2. External Cartridge Filter - Silencer Included with Filter 1. No Filter Do NOT remove fabric straps from filter. 3. External Tube Filters - 2. External Cartridge Filter 3.
  • Page 5 III. General Specifications & Fan Performance Curves 2hp Commercial System 2hp Commercial System Performance Curve Max. CFM = 1405 2HP Commercial Wood Dust Collector Owner’s Manual O.A.S. 2004...
  • Page 6 IV. Dimensions 2hp Outlet Detail For Minimum Mounting Heights *Dimensions subject to slight variation in manufacturing. Top View Always check the actual system height to determine your mounting height. Included Internal Silencer External Tube Filter Note: Check drum height, it will affect your bracket height.
  • Page 7 V. General Tube Filter Layout Dimensions Plenum can go to the right or left of the cyclone. Many configurations are possible. 2hp Cyclone with Fan Outlet can be rotated and External Filter External Filter oriented independent of inlet. Plenum 39” Plenum 62”...
  • Page 8: General Assembly

    VI. General Assembly Note: For cyclonic preseparation there must be an air tight seal between cyclone and dust container. Dust bin must be located vertically under cyclone, material drops down by gravity. 2HP Commercial Wood Dust Collector Owner’s Manual O.A.S. 2004...
  • Page 9: Bracket Assembly

    VII. Bracket Assembly Note: When installing the brackets on a concrete wall, mount 2 x 4’s between wall and brackets to stabilize and dampen vibration. Note: Please do not install an Oneida Dust Collection System alone. Competent assistance is advisable. Units are heavy! 2HP Commercial Wood Dust Collector Owner’s Manual O.A.S.
  • Page 10 VIII. General Assembly Instructions - All Models Wiring should be done by a licensed electrician! (See Wiring diagram section) See Fig. 1 See Fig. 2 See Fig. 3 IMPORTANT: Stay clear of fan exhaust while collector is operating. For External Cartridge, Tube Filter or No Filter models See Filter Assembly Section, pages 10 &...
  • Page 11: Filter Assembly

    IX. Filter Assembly No Filter Assembly Note: Do not return exhaust air to the shop unless filter media is added. Caution: External Filter Assembly 39” *Silencer Included. Do not remove foam from around wire cage! This is part of silencer! For Filter cleaning instructions, see pg.
  • Page 12 External Filter Assembly 62” Do not remove bands. X. Fan Outlet Transition, Silencer and Angle Iron Stand O.A.S. 2004 2HP Commercial Wood Dust Collector Owner’s Manual...
  • Page 13 XI. External Filter Bag Assembly See additional Plenum instruction sheet for 5 hole single row. Build your own plenum Note: The number of filters and hole configurations vary. Check with a sales technician if you have questions. 2HP Commercial Wood Dust Collector Owner’s Manual O.A.S.
  • Page 14 XII. Fan / Blower Wiring Diagram Wiring should always be done by a licensed electrician! Before Operation Electrical Wiring 2hp Fan / Blower Wire Diagram - Single & Three Phase Single Phase Three Phase Single Phase Three Phase Low Voltage Low Voltage High Voltage High Voltage...
  • Page 15: Filter Maintenance

    XIII. Filter Maintenance External Filter Cartridge Cleaning Intervals * WARNING: A close, direct blast with the compressed air nozzle too close to filter, may damage filter media. Always wear safety glasses while blowing off filter. Do not remove straps around pleats. External Filter Bags Caution: Fine dust collected in filter is hazardous to your health! Do not breathe!
  • Page 16 XIV. Options Square-to-Round Flex Hose Splitter Kit Fiber or Steel Dust Bins Our stock drums range from 34” to 35 3/4”. Bag Hold-Down System Enables you to line your dust drum with a plastic bag for easy, safe dust disposal. Stand - 2hp Angle Iron Wall Bracket SMS200000...
  • Page 17: Troubleshooting

    Poor Dust Pick-Up at Woodworking Machines Improper motor rotation - Running backwards will reduce suction by 30%. Filter Clogging Note: If you continue to experience difficulty with your collector call Oneida Air Systems at 1-800-732-4065 for assistance. 2HP Cyclonic Wood Dust Collector Owner’s Manual...
  • Page 18 XVI. Fire Hazards - Read Before Installing and Operating Oneida Collectors are designed for WOOD DUST only!! Until this type of fire has been witnessed, it is difficult to believe the devastation. This type of fire is rare but worth safeguarding against. The following points are worth heeding: The customer assumes the responsibility for contacting their insurance underwriter with regard to specific application requirements of explosion venting or if additional fire protection and safety equipment may be...
  • Page 19: Terms And Conditions

    XVII. Terms and Conditions Checking in Order Limited Warranty *Note: Motors should be protected from extreme weather to prolong motor life. Single phase motors should only be started and stopped up to 4 - 10 times per hour. Starting single phase motors more frequently can cause heat build up and can cause the motor overload to trip or cause motor damage.
  • Page 20 XVIII. Directions for Cleaning External Filter All steps should be done with a dust mask and eye protection. The External Filter can be cleaned using the following methods: 1. Compressed air from outside. 2. Empty Dust Bin. 3. Rinse with water. (Optional) INSIDE 2HP Commercial Wood Dust Collector Owner’s Manual O.A.S.