Multipoint Calibration - Genelec GLM 4 System Operating Manual

Loudspeaker manager glm
Hide thumbs Also See for GLM 4:
Table of Contents

Advertisement

Genelec Loudspeaker Manager (GLM) 4 - System Operating Manual

7.15.1 MultiPoint calibration

GLM supports unlimited number of microphone positions in the 'MultiPoint' mode.
The steps of a MultiPoint calibration are
select 'MultiPoint' in the AutoCal window (additional microphone positions can be measured
after the primary position)
place the microphone in the primary listening position
press the 'Start Calibration' button to start the measurement and follow the dialogue
instructions – keep on selecting new measurement positions as long as needed, following
the dialogue instructions
wait until all the measurement sweeps have been completed for all monitors and
subwoofers, the press the 'Optimize' button to start the calculation process and wait until
completed
review the results by clicking on the monitor and subwoofer icons
continue to AutoPhase when there is a subwoofer in the system – before running the
AutoPhase, move the microphone to the primary (first) microphone position and follow the
dialogue instructions
continue to WooferCal when there is a W371 woofer in the system – before running the
AutoPhase, move the microphone to the primary (first) microphone position and follow the
dialogue instructions
accept the calibration result with the 'Confirm Calibration' button
Figure 32. Selecting the MultiPoint calibration
page 59 of 87