7.9 Standalone Startup Level

By default, SAM subwoofers and monitors start up at the maximum output level. This is the output
level that get when adjusting the master level setting to the maximum (0 dB) in the GLM user
interface. It is possible to set the startup level to a lower value. To do this,
set the master level fader to the level you want to have at start-up
store this level permanently into the monitors and subwoofer with the other acoustic
settings, using the 'Group Preset' menu item 'Store to Loudspeakers' menu item.
Early SAM models (like 8240A, 8250A etc.) need a firmware update before the Startup level can
be stored. The Startup Level is overridden by GLM so when the GLM is running the level is set by
GLM, and when using the GLM adapter is powered without a computer and connected to the wired
volume control device.
Setting Startup level (sets a specified output level for all online devices):
1. Select a group that has desired acoustic settings and adjust the master level fader to the
desired value.
2. Store this level as the Startup level with other Group Settings clicking 'Group Preset: Store
to Loudspeakers' menu command, adjusting the 'Startup Level (dB)' in the 'Store Group
Settings' page and clicking 'Store' button.
To clear the Startup level (this sets the level to full output level for all online devices): **********
1. Select a group that has the desired acoustic settings.
2. Store this level as the Startup level with other Group Settings clicking 'Group Preset : Store
to Loudspeakers' menu command, set 'Startup Level' value to 0.0dB in the 'Store Group
Settings' page and clicking 'Store' button.
NOTE: The monitor or subwoofer can become very quiet if the 'Startup Level' is set to a low value.

7.10 Displaying monitor and subwoofer data in GLM

Several types of information for each monitor and subwoofer can be displayed in the GLM main
window by using the right click and selecting Show Info. These include
Name : monitor and subwoofer name
Barcode : barcode (Serial number) of the monitor or subwoofer.
Serial : Unique identifier of the monitor or subwoofer.
Status: Shows current status of the monitor or subwoofer.
Solo/Mute : to view solo and mute buttons for each monitors and subwoofers.
Stored -switch position : to view a switch state easily
I/O Levels : input and output signal levels for each monitor and subwoofer
Temp : to view a temperature inside a monitor or subwoofer
Bass Management : bass management crossover frequency
Flatness % / Correlated % : to view quality number for the woofer system (see
1)
1)
1) 2)