Genelec GLM 4 Quick Setup Manual

Genelec GLM 4 Quick Setup Manual

Hide thumbs Also See for GLM 4:

Advertisement

Quick Links

Advertisement

Table of Contents
loading

Summary of Contents for Genelec GLM 4

  • Page 2: Register Your Product

    1 REGISTER YOUR PRODUCT Please register your Genelec products at www.community.genelec.com and learn more about warranty. By joining the Genelec Community, you’ll be able to use all GLM Cloud features, ask questions, share experiences and participate in discussions with Genelec users globally. More information about service and technical support is available at www.genelec.com/customer-service.
  • Page 3: Placing Sam Monitors And Subwoofers In The Monitoring Room

    Aim each SAM monitor towards the listening position. This becomes your System Layout. More info about the correct monitor placement available at https://www.genelec.com/monitor-placement 1. Select listening position so that distances from side walls (B) are equal. 2. Place monitors so that distances to the listening position are equal, and distances to the monitors are equal from side walls (A).
  • Page 4: Analog Stereo With A Subwoofer Example

    Figure 1. Place monitors symmetrically relative to the walls. Point the acoustical axes towards the listening position. Analog Stereo with a Subwoofer Example Before cabling, turn off the power in all monitors and subwoofers. • Connect (Left) audio cable from the source to the subwoofer connector ANALOG IN 1.
  • Page 5: Cabling Of The Control Network

    USB (type B) Connects the GLM adapter to a computer USB interface or USB power supply (stand-alone volume control) Volume (3.5 mm jack) Connection for Genelec volume controller Microphone (3.5 mm jack) Connection for Genelec calibration microphone GLM Net (RJ45)
  • Page 6 Figure 3. Connections of GLM control network, measurement microphone, and computer...
  • Page 7: Downloading And Installing Glm Software

    Downloading and Installing GLM Software The GLM software calibrates and controls Genelec SAM systems. The software can be downloaded at www.genelec.com/glm. You must have sufficient rights to install the software in your computer. Install the software following the instruction given by the software during the installation process.
  • Page 8: Creating A Sam Monitor Layout

    Creating a SAM Monitor Layout To create a layout all monitors, subwoofers and woofer systems must be powered and GLM network connections be made. A layout defines your monitors and their locations in the room. An example in Figure 5 shows a stereo system with a subwoofer. A new system layout is created when the GLM user interface starts the first time.
  • Page 9 Figure 5. Drag and drop the monitor icons onto the layout grid to build a system layout. Creating a Group Preset A group preset is a set of monitors and subwoofers that reproduce audio together. A group preset contains input and acoustic settings to optimize all monitors and subwoofers active within the group.
  • Page 10 crossover selection below. If the setting is an individual, then crossover selections will be done individually for each monitors via a settings popup 4. Settings popup will popup when the monitor icon is clicked. 5. Name the monitor. 6. Make a monitor active or inactive within the group. 7.
  • Page 11: Automatic Calibration Using Glm Autocal

    Automatic Calibration Using GLM AutoCal GLM AutoCal is a powerful monitoring system calibration algorithm running in the Genelec Cloud. Sweeps are generated by each monitor in a group. Responses are recorded with the GLM measurement microphone into your computer. NOTE: Adaptive Woofer Systems will be calibrated in WooferCal page after Autocal and Autophase.
  • Page 12 Each setup file can contain several monitoring group preset definitions each with different AutoCal calibration settings. Even with the same set of monitors you can determine several listening positions by applying calibration in several locations and defining each location as a new group preset.
  • Page 13: Aligning Subwoofer Phase With Glm Autophase

    Figure 7. Steps in running the AutoCal automatic system calibration process Aligning Subwoofer Phase with GLM AutoPhase The purpose of GLM AutoPhase is to set the subwoofer phase at the crossover frequency in relation to a selected monitor so that the combined response of the subwoofer-monitor system is flat across the crossover region.
  • Page 14: Basic Use Of Glm

    3. Click ‘Confirm Calibration’ button to accept and save the calibration to the setup file. If there are several subwoofers in the group, the AutoPhase will move to the next subwoofer automatically. Figure 8. Steps in running the AutoPhase automatic phase calibration process Basic Use of GLM The main page of the GLM software offers the basic monitoring system controls (Figure 9)
  • Page 15 4. Dim (-20dB). 5. Standard loudness SPL level (calibration from ‘Group Preset : Standard Loudness SPL Calibration’ menu) 6. Level preset selections (to set adjust the system level at desired level and click ‘Group Preset : Set Preset Levels : Set Current Level to Preset1 ) 7.
  • Page 16 Figure 9. GLM software main page. Importing GLM3 Setup GLM3 Setup file can be imported to GLM4. Import function will import selected GLM3 setup file. GLM3 setup file remains untouched and can be used with GLM3. NOTE: GLM4 setup file cannot be opened with GLM3. Follow these steps: 1.
  • Page 17 3. Select a GLM3 setup file to be imported and click ‘Open’.The imported setup will be stored with same name to the GLM4. Figure 11. Selecting a setup to be imported from the GLM3 setup folder. 4. The GLM3 is now imported to the GLM4. All other settings than the layout are kept same, acoustic settings, groups etc.
  • Page 18 • Select level calibration standard from the dropdown list. • Place the Genelec calibration microphone at the listening position. • Click the ‘Start Calibration’ to start the calibration process. Note that the test signal may be loud. If the background noise in the room is more than 65 dB SPL, the loudness preset cannot be calibrated.
  • Page 19: Sound Character Profiler Tool

    After SPL calibration, the main page shows the preset levels in dB SPL units, and the Level Preset 1 is set at the standard level, e.g. 73 dBSPL for EBU R128. (Notice the graphical link-line between the Cal. Level and Level Preset 1 keys). To remove the Standard SPL calibration open the calibration page and select ‘Remove Calibration’...
  • Page 20 After setup, monitors, subwoofers and the GLM adapter can also operate without having a computer connected to the GLM adapter. This is called stand-alone operation. SAM monitors and subwoofers retain their settings after storing the settings inside the monitors and subwoofers. In some models the ‘Stored Controls’ switch need to be turned ON to make monitor to use stored settings in stand-alone mode.
  • Page 21: Status Indicators

    Status indicators GLM will show the status information of the system in GLM main page. On the to right corner you see whole system status as text. There is three status messages: Status: OK (all devices are online), Status: LS Offline (One or more loudspeakers in the current group preset is online), Status: Adapter Offline (GLM adapter is offline and any loudspeakers cannot be controlled).
  • Page 22 With the valid user account log in is possible from ‘User:Login’ menu. Log in To log in to the Genelec Cloud, valid user name and password to the Genelec community. Figure 17. Login to Genelec Community window.
  • Page 23: More Detailed Information

    Figure 18. User information and Log out window. MORE DETAILED INFORMATION More detailed information is available on the Genelec web site and GLM, monitor and subwoofer operation manuals. Please visit the GLM product page to download the GLM Operating Manual with detailed information about GLM software https://www.genelec.com/glm...
  • Page 24: Safety Considerations

    • The Genelec products and accessories can come with instructions on the proper methods of installation and use. Follow these instructions.
  • Page 25 Phone +86 400 700 1978 Email genelec.china@genelec.com In Japan Genelec Japan Inc 2-22-21 Akasaka Minato-ku JP-107-0052 Tokyo Japan Phone +81 3 6441 0591 Email genelec.japan@genelec.com www.genelec.com Genelec Document D0183R001. Copyright Genelec Oy 6.2020. All data subject to change without prior notice...

Table of Contents